Table 1. Recommended Line Fuse Sizes
90 VDC Motor
180 VDC Motor
Max. DC Armature
AC Line Fuse
Horsepower
Horsepower
Current (amps)
Size (amps)
1/20
1/10
0.5
3
1/15
1/8
0.8
3
1/8
1/4
1.5
5
1/6
1/3
1.7
5
1/4
1/2
2.5
8
1/3
3/4
3.5
8
1/2
1
5.0
10
3/4
1 1/2
7.5
15
1
2
10
20
Minarik Corporation offers two fuse kits: part number 050–0069
(3–8A Fuse Kit) and 050–0073 (5–20A Fuse Kit). Both fuse kits
include a 1/2A pico fuse (part number 050–0064) which protects
the transformer and logic.
12
Installation
Wire an external line fuse between the stop switch (if installed) and
the terminal board. An additional line fuse should be installed on
L2 if the input voltage is 230 VAC. Refer to the line fuse chart
below for fuse ratings.