37
Independent Adjustable Speeds
Connect two speed adjust potentiometers with a single-pole, two
position switch to select between two independent speeds shown
in the forward direction (Figure 19). The speed adjust
potentiometers can be mounted at two separate operating stations.
S1
S2
C509
S0
SPEED 2
SPEED 1
SPEED 2
20K OHMS
SPEED 1
20K OHMS
CW
CW
P1
P2
C510
+
1
5
C512
S3
C511
COMMON
DC VOLTAGE
DC VOLTAGE
Figure 19. Independent Adjustable Speeds (Forward Direction)