![Minarik MMRG Series User Manual Download Page 24](http://html1.mh-extra.com/html/minarik/mmrg-series/mmrg-series_user-manual_1800547024.webp)
16
Voltage follower (-PCM models)
PCM series drives can be configured to follow a grounded (non-
isolated) voltage signal. To configure the drive to follow a voltage
signal, connect the signal leads to the SIGNAL INPUT POS and
SIGNAL INPUT NEG terminals, observing proper polarity. Note:
There are two locations where signal input connections can be
made, either to terminals TB501 or to the fast-on terminal posts
located below TB501. (see figure 9, page 17)
Polarity reversal switch (-PCM models)
To reverse the output voltage polarity without changing the input
polarity, connect DIR to COM. A single-pole, single-throw switch
can be used as a polarity reversal switch. Close the switch to
reverse the output voltage polarity. Open the switch to return the
output voltage back to its original polarity. See Figure 9, page 17
for polarity reversal switch connections.