22
Warning
Decelerating to minimum speed, regenerative braking, or
coasting to a stop is recommended for frequent starts and
stops. Do not use any of these methods for emergency
stopping. They may not stop a drive that is malfunctioning.
Removing AC line power (both L1 and L2) is the only
acceptable method for emergency stopping.
For this reason,
Minarik strongly recommends installing an
emergency stop switch on both the L1 and L2 inputs
(see
Connections
section - page 11).
Frequent decelerating to minimum speed or regenerative
braking produces high torque. This may cause damage to
motors, especially gearmotors that are not properly sized for
the application.
Automatic restart upon power restoration
All drives automatically run to set speed when power is applied.
Operation
Starting and Stopping Methods