Connecting Cables
1-11
1
Be
fore Use
3
4
5
6
Removing USB memory
If a USB memory module is inserted in the personal computer to which a TS500 machine is connected, click
"Stop" in the "Safely Remove Hardware" window by following the instructions given there first and then remove
the module.
Leaving a USB memory module inserted can cause [ERROR 201 COMMAND ERROR].
Copy the data onto the hard disk before outputting it for printing.
Connecting Power Supply Cable
You are not allowed to install the printer by yourself. Be sure to request MIMAKI’s service personnel and an
electrician to install the printer.
For power supply connection, this printer uses the Type B plug and socket in compliance with IEC 60309.
When a socket construction meeting the plug of the power cable of this printer is required, use the supplied
socket and perform construction between your switchboard and the socket.
• The power supply specifications of this machine is as below:
Single-phase 200 to 240 Vac 20 A or less (cannot be used with 100 V system)
• For the power supply to the main body of the printer, electrical work is required as described below.
Request an electrician to perform electrical work.
Socket installation onto the circuit breaker
Grounding work
• Ensure that a wall outlet is available near the printer. Also ensure that the power cable can be easily
unplugged whenever necessary.
• To prevent electrical shock hazard, it is prohibited for anyone other than electrician licensees to
perform the electrical work for this printer.
• Take care not to miswire, which can result in a fire or an electric shock.
• When any power cable other than the supplied one is to be used, make sure that the cable is
equivalent to one of the following types. Connect the cable as shown below.
VCT-5.5m m
2
x33 cores (600 V)
UL-AWG10x3C (600V)
Side of the
printer body
Switchboard
Socket
Power cable:
UL AWG10 or the
equivalent
Supplied socket
Socket
construction
Socket construction
Circuit breaker
1
φ
200V to 240V 30A
Switchboard