Troubleshooting
5-7
1
1
1
1
5
T
roubleshooting
If nozzle missing due to color mixture of ink or aeration
If nozzle missing occurs due to color mixture of ink in the head or aeration, push ink or air in the head out from
the port.
1
Select [AIR PG] of the maintenance menu.
(1)
Press the
key in LOCAL.
(2)
Press
to select [MAINTENANCE] and press the
key.
(3)
Press
to select [AIR PG].
2
Press the
key.
3
Remove the right front cover and the right
maintenance cover, and then remove head cover.
4
Press the
key.
5
Discharge the ink from the valve of the Y-port.
• Insert the syringe into the valve of Y-port and then slowly
withdraw about 10cc of the ink.
• While performing the work below, ink may leak from the cap part.
Using a waste cloth etc., prevent ink stain on the valve part.
• Be careful not to spatter the ink around during
the work.
• Mask the around valves properly with the waste
cloth or adequate materials in order to protect
the circuit board that is closely placed.
PREPARE A I R PG
COMP L E T ED
[ ENT ]
Right front cover
Right maintenance cover
A I R PG
S T ART
[ ENT ]