- 6.8 -
ERROR 11
PARAMETER
ERROR 14
COLOR COMMAND
ERROR 20
I / F BOARD
ERROR 21
THERE IS NO I / F
ERROR 23
HOST I / F
ERROR 24
I / F INITIAL
ERROR 30
OPERATION
ERROR 34
DATA REMAIN
ERROR 40
MOTOR X
ERROR 41
MOTOR Y
ERROR 42
X OVERCURRENT
ERROR 43
Y OVERCURRENT
ERROR 45
CAPPING
A parameter outside the range of
acceptable numeric values is
received.
Strange color data has been
received.
Improper operation has been
conducted on the operation panel.
No I/F board is attached to the
control board.
HOST I/F Timeout error has
arisen during communication
between the host computer and
interface board.
Initial operation failure of the I/F
board and control board.
An error occurs on the interface
between the I/F board and the
control board.
Settings for functions have been
changed to be changed though
there remains received data that
has not yet been printed.
The Xmotor has been overload.
The Ymotor has been overload.
Overcurrent error on the Xmotor
has been detected.
Overcurrent error on the Ymotor
has been detected.
Incorrect height of the capping
station has been detected.
Check the host computer output
setting.
Turn off the power to the machine
for a while and then turn it on. If
the same error message appears
again on the LCD, contact your
local distributor for service.
Check to be sure that the cable is
securely connected to the host
computer and interface board.
Also, check to ascertain that no
error has arisen on the host
computer side.
Turn off the power to the machine
for a while and then turn it on. If
the same error message appears
again on the LCD, contact your
local distributor for service.
Perform a proper operation.
Print all pieces of received data or
execute the data clear function.
Then, change the settings.
Turn off the power to the machine
for a while and then turn it on. If
the same error message appears
again on the LCD, contact your
local distributor to call for
service.
Warning message
Cause
Corrective measure
Summary of Contents for DM2-1810
Page 2: ......
Page 18: ...xiv...
Page 72: ...3 20...
Page 98: ...5 18...
Page 108: ...6 10...
Page 116: ...A 8...
Page 117: ...A 9 Function flowchart...
Page 119: ...A 11 Filling 00 00 00 Display remaining time Function flowchart...
Page 129: ...A 21 TYPE Refresh Level3 TYPE mm inch mm X Level0 Level3 X inch Function flowchart...
Page 143: ...A 35...
Page 144: ...D201256 1 10 02082005...
Page 145: ......
Page 146: ...PrintedinJapan MIMAKI ENGINEERING Co Ltd TI TM...