SYMBOLOGY

 

  

Volts

 

 

Direct Current

 

 

Alternating Current

 

  Double Insulated

 

C

US

  UL Listing for Canada and U.S.

 

 

CAUTION

Bright Light - 

 

 

Do Not Stare Into Light 

 

 

Read operator's manual

SPECIFICATIONS

Cat. No. ..................................................... 2144-20

Battery Type .................................................

M18™

Charger Type

 ................................................

M18™

DC Input Volts

......................................................

18

AC Input Volts

 ....................................................

120

AC Input Amps

....................................................0.6

GROUNDING

DANGER

Improperly connecting the ground-

ing wire can result in the risk of 

electric shock. Check with a qualified electrician 

if you are in doubt as to whether the outlet is 

properly grounded. Do not modify the plug pro-

vided with the tool. Never remove the grounding 

prong from the plug. Do not use the tool if the 

cord or plug is damaged. If damaged, have it 

repaired by a MILWAUKEE service facility before 

use.  If  the  plug  will  not  fit  the  outlet,  have  a 

proper outlet installed by a qualified electrician.

Grounded Tools (Three-Prong Plugs)

Tools  marked  “Grounding  Required”  have  a  three 

wire cord and three prong grounding plug. The plug 

must be connected to a properly grounded outlet 

(See  Figure A).  If  the  tool  should  electrically  mal

-

function or break down, grounding provides a low 

resistance path to carry electricity away from the 

user, reducing the risk of electric shock.

The grounding prong in the plug is connected through 

the green wire inside the cord to the grounding 

system in the tool. The green wire in the cord must 

be the only wire connected to the tool's grounding 

system and must never be attached to an electrically 

“live” terminal.

Your tool must be plugged into an appro-

Fig. A

priate outlet, properly installed and 

grounded in accordance with all codes 

and ordinances. The plug and outlet 

should look like those in Figure A.

Double Insulated Tools (Two-Prong Plugs)

Tools marked “Double Insulated” do not require ground

-

ing. They have a special double insulation system which 

satisfies OSHA requirements and complies with the 

applicable standards of Underwriters 

Fig. B Fig. C

Laboratories, Inc., the Canadian Stan

-

dard Association and the National Elec-

trical Code. Double Insulated tools may 

be used in either of the 120 volt outlets 

shown in Figures B and C. 

EXTENSION CORDS

Grounded tools require a three wire extension 

cord. Double insulated tools can use either a two 

or three wire extension cord. As the distance from 

the supply outlet increases, you must use a heavier 

gauge extension cord. Using extension cords with 

inadequately sized wire causes a serious drop in 

voltage, resulting in loss of power and possible tool 

damage. Refer to the table shown to determine the 

required minimum wire size.

The smaller the gauge number of the wire, the greater 

the capacity of the cord. For example, a 14 gauge 

cord can carry a higher current than a 16 gauge cord. 

When using more than one extension cord to make 

up the total length, be sure each cord contains at 

least the minimum wire size required. If you are using 

one extension cord for more than one tool, add the 

nameplate amperes and use the sum to determine 

the required minimum wire size.

Guidelines for Using Extension Cords

• If you are using an extension cord outdoors, be sure 

it is marked with the suffix “W” to indicate that it is 

acceptable for outdoor use.

• Be sure your extension cord is properly wired and in 

good electrical condition. Always replace a damaged 

extension  cord  or  have  it  repaired  by  a  qualified 

person before using it.

• Protect your extension cords from sharp objects, 

excessive heat and damp or wet areas.

• When stringing lights together, consider the total 

Amperes draw when selecting the extension cords.

Recommended Minimum Wire Gauge

For Extension Cords*

Extension Cord Length

Nameplate

Amperes

25'

50'

75'

100' 150'

0 - 2.0

2.1 - 3.4

3.5 - 5.0

5.1 - 7.0

7.1 - 12.0

12.1 - 16.0

16.1 - 20.0

18

18

18

18

16

14

12

18

18

18

16

14

12

10

18

18

16

14

12

10

--

18

16

14

12

10

--

--

16

14

12

12

--

--

--

* Based on limiting the line voltage drop to five volts at 150% 

of the rated amperes.

READ AND SAVE ALL INSTRUCTIONS 

FOR FUTURE USE.

ASSEMBLY

WARNING

Recharge only with the charger 

specified for the battery. For spe

-

cific charging instructions, read the operator’s 

manual supplied with your charger and battery.

Inserting/Removing the Battery

Insert

 the battery pack by sliding battery pack into 

the body of the tool. Insert the battery pack until the 

battery latches lock. 

To

 remove

 the battery pack, press in both battery 

latches and slide the battery pack off of the tool.

Inserting/Removing Extension Cords

To operate the light on AC Power and plug in a suit

-

able extension cord into the light.

  

Summary of Contents for M18 RADIUS COMPACT SITE LIGHT WITH FLOOD MODE

Page 1: ...O DE REFLECTOR M18 ADIUS OPERATOR S MANUAL MANUEL de L UTILISATEUR MANUAL del OPERADOR WARNING To reduce the risk of injury user must read and understand operator s manual AVERTISSEMENT Afin de r duir...

Page 2: ...Do not use on a ladder or unstable support Stable footing on a solid surface enables better control of the light in unexpected situations BATTERY TOOL USE AND CARE Recharge only with the charger speci...

Page 3: ...wire extension cord Double insulated tools can use either a two or three wire extension cord As the distance from the supply outlet increases you must use a heavier gauge extension cord Using extensio...

Page 4: ...AND REPLACEMENT REMEDIES DESCRIBED HEREIN IS A CONDITION OF THE CON TRACT FOR THE PURCHASE OF EVERY MILWAUKEE PRODUCT IF YOU DO NOTAGREE TO THIS CONDITION YOU SHOULD NOT PURCHASE THE PRODUCT IN NO EVE...

Page 5: ...vent cor respondre la prise secteur utilis e Ne jamais modifier la fiche de quelque fa on que ce soit Ne jamais utiliser d adaptateurs de fiche avec des outils mis la terre Les fiches et prises non mo...

Page 6: ...S No de Cat 2144 20 Type de batterie M18 Type de chargeur M18 Tension d entr e CD 18 Tension d entr e CA 120 Amp rage d entr e CA 0 6 PICTOGRAPHIE Volts Courant direct Courant alternatif Double Isolat...

Page 7: ...du cordon de rallonge m 7 6 12 2 22 8 30 4 45 7 60 9 0 5 0 5 1 8 0 8 1 12 0 12 1 15 0 15 1 20 0 16 16 14 12 10 16 16 14 12 10 16 14 12 10 10 14 12 10 10 12 10 12 Bas sur sur une chute de voltage limi...

Page 8: ...garantie n est pas n cessaire pour b n ficier de la garantie en vigueur sur un outil lectrique MILWAUKEE La date de fabrication du produit servira tablir la p riode de garantie si aucune preuve d ach...

Page 9: ...po demasiado Mantenga un buen contacto entre los pies y el suelo y mantenga el equilibrio en todo momento Esto permite un mejor control de la herramienta el ctrica en situaciones inesperadas No se uti...

Page 10: ...l nico hilo conectado al sistema de conexi n de puesta a tierra de la herramienta y nunca se debe unir a una terminal energizada Su herramienta debe estar enchufada en un tomacor riente apropiado corr...

Page 11: ...esione el bot n MODE modo para seleccionar rea o inundaci n de l mpara La l mpara usar de manera predeterminada el rea seleccionada la siguiente vez que se encienda 5 Presione el bot n de encendido pa...

Page 12: ...ONSABLE EN NING N CASO DE DA OS INCIDENTALES ES PECIALES EMERGENTES O PUNITIVOS NI DE NING N COSTO HONORARIOS LEGALES GASTOS P RDIDAS O DEMORASALE GADOS COMO CONSECUENCIA DE ALG N DA O FALLA O DE FECT...

Reviews: