4
1 - Orbit control switch
2 - Handle adjustment button
3 - Handle
4 - Quik-Lok
®
cord
5 - Trigger
6 - Insulating boot
7 - Shoe release lever
8 - Adjustable pivot shoe
9 - Blade
10 - Quik-lok
®
blade clamp
For additional safety instructions, read Safety Instruction book No. 58-13-0000. Sound and Vibration information.
•
Typically the A-weighted sound pressure level of the tool is less than 85 dB (A). The noise level when working can exceed 96 dB (A). Wear ear protection!
•
The typical weighted acceleration is less than 24 m/s
2
.
These declared values were obtained by laboratory type testing in compliance with the stated standards and are not adequate for use in risk
assessments. Values measured in individual work places may be higher than the declared values. The actual exposure values and risk of harm
experienced by an individual user are unique and depend upon the way the user works, the work piece and the workstation design, as well as upon
the exposure time and the physical condition of the user.
We, Milwaukee Electric Tool Corp., cannot be held liable for the consequences of using the declared values, instead of values reflecting the actual
exposure, in an individual risk assessment in a work place situation over which we have no control.
Sawzall Hatchet
TM
English
Assembly
WARNING!
To reduce the risk of injury, always unplug the tool before changing
accessories or making adjustments. Use only specifically recom-
mended accessories. Other may be hazardous.
Removing and Replacing Quik-Lok
®
Cords
MILWAUKEE’S
exclusive Quik-Lok
®
Cords provide instant field replace-
ment or substitution.
1.
Unplug the tool.
2.
To remove the Quik-Lok
®
Cord, turn the cord nut 1/4 turn to the left and
pull it out.
3.
To replace the Quik-Lok
®
Cord, align the connector keyways and push
the connector in as far as it will go. Turn the cord nut 1/4 turn to the right
to lock.
Selecting a Blade
The Quik-Lok
®
Blade Clamp can be used with all 13 mm shank universal
Sawzall
®
blades. Use
MILWAUKEE
High Performance Super Sawzall
®
blades for best performance. When selecting a blade, choose the right
type and length.
Installing and Removing Blades Quik-Lok
®
Blade Clamp
11 - Collar
12 - Blade
Unplug the tool. Make sure the spindle and blade clamp areas are clean.
Metal chips and sawdust may prevent the Quik-Lok
®
Blade Clamp from
clamping securely.
1.
Depending on the job, the blade may be inserted with the teeth facing
up or down. To install a blade, twist collar in the direction of the arrow
while inserting the blade into the clamp until the tang butts against the
collar.
2.
Release collar and the spring loaded mechanism will clamp the blade
firmly in place.
3.
Twist collar in the opposite direction of the arrow to ensure that the blade
is locked into the clamp.
4.
Tug on blade to make sure it is securely locked in place.
5.
To remove a blade, twist collar in the direction of the arrow while pulling
on the blade. Be careful when handling hot blades.
Symbology
Read operator's manual before using this tool.
CE Conformity Mark
No Load Strokes Per Minute
SEMKO safety
A
B
C
Amperes
Double Insulated
Volts Alternating Current
Straight Cut
Orbital Cut
Specifications
Strokes
per Minute
0 - 3 000
Volts
AC
220-240
Length of
Stroke
19 mm
Cat.
No.
SSH 800 QX
Article
No.
6524-51
Amps
3,7