SPECIFICATIONS

Fig. B Fig. C

Fig. A

GROUNDING

Grounded Tools: Tools with Three Prong Plugs

Tools marked “Grounding Required” have a three 
wire cord and three prong grounding plug. The 
plug must be connected to a properly grounded 
outlet (See Figure A). If the tool should electrically 
malfunction or break down, grounding provides a 
low resistance path to carry electricity away from 
the user, reducing the risk of electric shock.
The grounding prong in the plug is connected 
through the green wire inside the cord to the 
grounding system in the tool. The green wire in the 
cord must be the only wire connected to the tool's 
grounding system and must never be attached to 
an electrically “live” terminal. Your tool must 
be plugged into an appropriate outlet, prop-
erly installed and grounded in accordance 
with all codes and ordinances. The 
plug and outlet should look like those 
in Figure A.

Double Insulated Tools: Tools with Two Prong 
Plugs

Tools marked “Double Insulated” do not require 
grounding. They have a special double insulation 
system which satisfi es OSHA requirements and com-
plies with the applicable standards of 
Underwriters Laboratories, Inc., the 
Canadian Standard Association and 
the National Electrical Code. Double 
Insulated tools may be used in ei-
ther of the 120 volt outlets shown in 
Figures B and C.
In specifi c countries, double insulated tools could 
be used in the output 
connections suitable 
for the plug.

WARNING

 Improperly connecting the 

grounding wire can result in the risk of elec-
tric shock. Check with a qualifi ed electrician 
if you are in doubt as to whether the outlet is 
properly grounded. Do not modify the plug 
provided with the tool. Never remove the 
grounding prong from the plug. Do not use 
the tool if the cord or plug is damaged. If 
damaged, have it repaired by a MILWAUKEE 
service facility before use. If the plug will not 
fi t the outlet, have a proper outlet installed by 
a qualifi ed electrician.

Cat. No.

Volts AC

W

RPM

Spindle Thread Size

Wheel Size

6149-59

6149-59A
6149-59B

6117-59

6117-59A

220-240 50-60 Hz
220-240 50-60 Hz

127V 50-60 Hz

220-240 50-60 Hz
220-240 50-60 Hz

1200
1200
1200
1550
1550

11,000
11,000
11,000

2,800 - 11,000
2,800 - 11,000

5/8"-11
5/8"-11
5/8"-11
5/8"-11
5/8"-11

4 1/2"
4 1/2"
4 1/2"

5 "

4 1/2"

Grounded tools require a three wire extension 
cord. Double insulated tools can use either a two 
or three wire extension cord. As the distance from 
the supply outlet increases, you must use a heavier 
gauge extension cord. Using extension cords with 
inadequately sized wire causes a serious drop in 
voltage, resulting in loss of power and possible tool 
damage. Refer to the table shown to determine the 
required minimum wire size.
The smaller the gauge number of the wire, the 
greater the capacity of the cord. For example, a 14 
gauge cord can carry a higher current than a 16 
gauge cord. When using more than one extension 
cord to make up the total length, be sure each cord 
contains at least the minimum wire size required. 
If you are using one extension cord for more than 
one tool, add the nameplate amperes and use the 
sum to determine the required minimum wire size.

Guidelines for Using Extension Cords

• If you are using an extension cord outdoors, be 

sure it is marked with the suffi x “W-A” (“W” in Cana-
da) to indicate that it is acceptable for outdoor use.

• Be sure your extension cord is properly wired 

and in good electrical condition. Always replace a 
damaged extension cord or have it repaired by a 
qualifi ed person before using it.

• Protect your extension cords from sharp objects, 

excessive heat and damp or wet areas.

READ AND SAVE ALL 

INSTRUCTIONS FOR FUTURE USE.

* Based on limiting the line voltage drop to fi ve volts at 

150% of the rated amperes.

EXTENSION CORDS

Recommended Minimum Wire Gauge 

or Extension Cords*

Nameplate

Amperes

Extension Cord Length

25'

50'

75'

100'

150'

0 - 2.0

2.1 - 3.4
3.5 - 5.0
5.1 - 7.0

7.1 - 12.0

12.1 - 16.0
16.1 - 20.0

18
18
18
18
16
14
12

18
18
18
16
14
12
10

8

18
16
14
12
10

--

18
16
14
12
10

--
--

16
14
12
12

--
--
--

Installing Side Handle

The side handle may be installed on either side 
of the gear case. Position the side handle in the 
location which offers best control and guard protec-
tion. To install, thread side handle into side handle 
socket and tighten securely.

WARNING

 To reduce the risk of injury 

when grinding:

• ALWAYS use the proper guard.
• ALWAYS properly install the guard.
• ALWAYS hold the tool fi rmly with both 

hands using the handles provided before 
and during grinding.

• NEVER use a wheel that has been dropped.
• NEVER bang grinding disc onto work.
• NEVER grind without proper safety 

equipment.

Installing, Removing and Adjusting the Guard

This tool is shipped with a guard. The guard must 
be used when using the tool as a grinder. The guard 
may be removed when using tool as a sander.
1. To 

remove

 the guard, unplug tool and remove 

any accessories from spindle.

2. Press in the lock lever and rotate the guard to line 

up the tabs on the grinder with the slots in the guard. 

3. Press in the lock lever and lift the guard straight 

up and away from the tool.

4. To 

install

 the guard, unplug the tool and remove 

any accessories from the spindle.

5. Line up the tabs on the grinder with the slots in 

the guard.

6. Press in the lock lever and press the guard onto 

the tool.

7. To 

adjust

 the guard, press in the lock lever and 

rotate the guard to one of fi ve detent slots. 

WARNING 

Only use accessories with 

Maximum Safe Operating Speed rated at 
least equal to the maximum speed marked 
on the power tool. This speed is based on 
the strength of the wheel, allowing for a 
reasonable measure of safety. It is not meant 
to imply a best or most effi cient  operating 
speed. Do not exceed the Maximum Safe 
Operating Speed.

ASSEMBLY

 WARNING 

To reduce the risk of injury, 

always unplug tool before attaching or remov-
ing accessories or making adjustments. Use 
only specifi cally recommended accessories. 
Others may be hazardous.

WARNING 

To reduce the risk of injury, 

wear safety goggles or glasses with side shields.

FUNCTIONAL DESCRIPTION

1. Side handle
2. Spindle lock
3. Side handle socket

1

4

5

6

3

2

4. Slide switch
5. Type 27 guard
6.  Guard lock lever

Installing/Removing Accessories 

Make sure the grinding wheel does not extend 
beyond the bottom of the guard. Threaded hub 
grinding wheels may require a deeper guard (see 
"Accessories").
1. Unplug the tool.
2. Properly position the guard. 

Tab 

slots

Fig. 1

Dentent

slots

Operator's Zones

Fig. 2

3. Wipe the flange, flange nut and spindle to 

remove dust and debris. Inspect the parts for 
damage. Replace if needed.

4. Place the fl ange on spindle, as shown.

Spindle

Flange

Grinding
wheel

Flange nut

Fig. 3

Summary of Contents for 6117-59

Page 1: ...F INJURY USER MUST READ AND UNDERSTAND OPERATOR S MANUAL 6117 59 6117 59A AMOLADORA ANGULAR DE 1200 WATTS 115 mm 4 1 2 ESMERILHADEIRA DE 1200 WATTS 115 mm 4 1 2 HEAVY DUTY SANDER GRINDER 1200 WATTS 4...

Page 2: ...fiere a su herramientaoperadaporconexi n cable alaredel ctricaopormediodeunabater a inal mbrica bajo la influencia de drogas alcohol o medici nas Despistarse un minuto cuando se utiliza una herramient...

Page 3: ...cesorio se caen inspecci nelos para ver si est n da ados o instale un accesorio que no est da ado Despu s de inspeccionar e instalar un accesorio mant ngase alejado y mantenga alejadas a las personas...

Page 4: ...realiza estas tareas Para reducir la ex posici n a estas sustancias qu micas trabaje en un rea bien ventilada y utilice equipo de seguridad aprobado como por ejemplo m scaras contra el polvo que haya...

Page 5: ...de la tuerca del adaptador con un disco de 3 2 mm 1 8 o menos de grosor Fig 4 3 2 mm 1 8 6 4 mm 1 4 Posici n de la tuerca del adaptador con un disco de 6 4 mm 1 4 de grosor 7 Presione el bot n de bloq...

Page 6: ...Oxido de aluminio Para desbaste r pido y aplicaciones generales en la mayor a de las operaciones en metal Ideal para acero rolado en frio acero inoxidable o metales que requieran abrasivos de larga v...

Page 7: ...de com cabo de rede e a ferramentas el tricas operadas a bateria sem cabo de rede Mantenha a sua rea de trabalho sempre limpa e bem iluminada Desordem ou reas de trab alho insuficientemente iluminadas...

Page 8: ...menta de trabalho esteja comple tamente parada A ferramenta de trabalho em rota o pode entrar em contacto com a superf cie de apoio provocando uma perda de controlo da ferramenta el ctrica N o permiti...

Page 9: ...assist ncia t cnica autorizada da MIL WAUKEE para obter a substitui o gratuita AVISO Certas poeiras geradas por lixas serras trituradores furadeiras el tricas e outras ativi dades de constru o cont m...

Page 10: ...na posi o ON Para interromper o funcionamento da ferramenta solte o bot o Certifique se de que a ferramenta esteja parada antes de coloc la sobre uma su perf cie Para travar o bot o coloque o na posi...

Page 11: ...de pintura de carros barcos etc sem causar obstru es Cer mica Dura at tr s vezes mais que discos de xido de alum nio Para trabalhos gerais em metal Ideal para trabalhos pesados Instala o de blocos de...

Page 12: ...cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock When o...

Page 13: ...he rotating acces sory Accessory may kick back over your hand Do not position your body in the area where power tool will move if kickback occurs Kick back will propel the tool in direction opposite t...

Page 14: ...sion cord outdoors be sure it is marked with the suffix W A W in Cana da to indicate that it is acceptable for outdoor use Be sure your extension cord is properly wired and in good electrical conditio...

Page 15: ...Allow accessory to come to full speed before beginning work 6 Control pressure and surface contact between accessory and workpiece Too much pressure slows speed 7 When finished turn off the tool and...

Page 16: ...l Tagdamaged tools DO NOT USE until repaired see Repairs Under normal conditions relubrication is not neces sary until the motor brushes need to be replaced After six months to one year depending on u...

Page 17: ...s Com rcio de Ferramentas do Brasil Ltda Prolongamento da Travessa Claudio Armando n 171 Bloco 2 galp o 21 Bairro Assun o S o Bernardo do Campo SP CEP 09861 730 Brasil CNPJ 11 857 988 0001 26 Importad...

Reviews: