Charge only 

MILWAUKEE

 7.2, 9.6 and 12 V battery packs in this

charger.  Other  types  of  batteries  may  explode  causing  per-

sonal  injury  and  damage.

WARNING!

When  to  charge  the  battery  pack

Charge your battery pack before you use your tool for the first time and when

your tool no longer performs with the power and torque needed for the job.

Never completely discharge the battery pack.

Standard  charging  times

Standard  charging  time  is  approximately  1/2  hour.  Charging  time  varies

depending  on  the  charge  needed  and  the  battery  pack  capacity.  For

example, if the battery pack does not require a full charge, the charging time

will be less than one and one-half hour. For nominal charge times, see chart

below.

Charging  (Fig.  1)

1. Plug the charger into a 120 volt AC outlet. Place the charger upright,

being careful not to block the vents.

Fig. 1

2. Insert the battery pack into the charger as far as possible.
    • If the battery pack is too warm, the charger will wait for it to cool

before charging the battery pack. While the charger is waiting for the

battery  pack  to  cool  the  amber  waiting  light  will  glow  and  the  red

charging light will be off.

    • In rare cases when the battery pack voltage is very low, the charger

will “precondition” the battery pack (bring the voltage up to an accept-

able  level)  and  automatically  begin  charging  the  battery.  While  the

charger is “preconditioning” the battery pack, the amber waiting light

will  glow.  When  charging  begins,  the  amber  waiting  light  will  be  off

and the red charging light will glow.

    • If the battery pack is cool enough and has an acceptable voltage level,

the charger will begin charging the battery pack. While the charger is

charging the battery pack, the amber waiting light will be off and the

red charging light will glow.

3. When  charging  is  finished,  the  red  charging  light  will  blink

indicating that the charger is maintaining the battery pack at full charge.

If you have followed the steps above and the charger does not work as

described:
    • Check the electrical contacts between the battery pack and charger.

If the contacts are dirty, clean them with a pencil eraser.

    • Check that the charger is plugged into the outlet.
    • Some obsolete battery packs will not charge in this charger. If one of

these battery packs is inserted in the charger, the amber waiting light

will  remain  on  and  the  battery  will  not  be  charged.  These  obsolete

battery packs may still be charged in older chargers.

If the charger still does not work, return the charger and battery pack to a

MILWAUKEE

  service  facility.

Effects  of  temperature  on  charging

Battery packs are affected by temperature. Your battery pack will perform

best and have the longest life if it is charged when the air temperature is

between 60°F - 80°F (15°C-27°C). Do not charge in temperatures below

40°F (5°C) or above 105°F (40°C). Under these conditions, the capacity will

be  reduced.

Automatic  Start

If  a  hot  battery  pack  is  inserted  into  the  charger,  charging  will  begin

automatically  once  the  battery  pack  cools  to  the  appropriate

temperature.

Maintenance  Charge

Nickel-cadmium  batteries  discharge  at  a  rate  of  about  1%  per  day.  The

”Maintenance Charge“ feature will keep the battery pack fully charged while

the  battery  pack  is  stored  in  the  plugged-in  charger.  The  maintenance

charge mode automatically begins after the battery pack is fully charged.

During maintenance charging, the amber light will be off and the red light will

blink.

Battery

Pack

48-11-0130
48-11-0080
48-11-0140
48-11-0200
48-11-0250
48-11-0300

Type

1.2 A/h
1.2 A/h
1.2 A/h
1.7 A/h
2.0 A/h
2.5 A/h

Voltage

7.2
9.6

12
12
12
12

Nominal

Charge

Times

30 min.
30 min.
30 min.
45 min.
50 min.
70 min.

Summary of Contents for 48-59-0192

Page 1: ...ERSTAND OPERATOR S MANUAL AFINDER DUIRELERISQUEDEBLESSURES L UTILISATEURDOITLIREETBIENCOMPRENDRELEMANUELDE L UTILISATEUR PARA REDUCIR EL RIESGO DE LESIONES EL USUARIO DEBE LEER Y ENTENDER EL MANUAL DE...

Page 2: ...Page 2...

Page 3: ...d result in the risk of fire and electrical shock If an extension cord must be used plug the charger into a properly wired This manual contains important safety and operating instructions for battery...

Page 4: ...ill be off and the red charging light will glow 3 When charging is finished the red charging light will blink indicating that the charger is maintaining the battery pack at full charge If you have fol...

Page 5: ...fice Service Center or dispose of your battery pack according to federal state and local regulations Repairs For repairs return the tool battery pack and charger to the nearest service center Battery...

Page 6: ...n risque d incendie de choc lectrique ou de blessure 8 N UTILISEZ PAS DE RALLONGE MOINS QUE CE NE SOIT ABSOLUMENT INDISPENSABLE L utilisation d une rallonge inadapt e endommag e ou d un c blage de mau...

Page 7: ...atterie au nickel cadmium s puise raison de 1 par jour Le dispositif de maintien de charge assurera la recharge constante tant que la batterie restera ins r e dans le chargeur et que celui ci sera bra...

Page 8: ...e de service ou la succursale MILWAUKEE la plus proche ou jetez la batterie en vous conformant aux r glements f d raux provinciaux et locaux R parations Pour les r parations retournez outil batterie e...

Page 9: ...cendio o de descarga el ctrica Si es necesario utilizar un cable de extensi n conecte el cargador a uno de calibre 16 o mayor debidamente cableado y cuyos conductores sean iguales en n mero tama o y f...

Page 10: ...la carga de mantenimiento se apagar la luz del color del mbar y se destellar la luz roja Carga 1 Enchufe el cargador en una toma el ctrica de CA de 120V Coloque el cargador en una posici n vertical c...

Page 11: ...dmio Las bater as de n quel cadmio son reciclables Es posible que bajo las leyes estatales y locales sea ilegal descartar este tipo de bater as en los flujos municipales de desechos Regrese las bater...

Page 12: ...0 729 3878 fax 1 800 638 9582 email metproductsupport milwaukeetool com Monday Friday 8 00 AM 4 30 PM Central Time CANADA Service MILWAUKEE MEXICO Servicios de MILWAUKEE Milwaukee Electric Tool Blvd A...

Reviews: