5

MILWAUKEE LI-ION 

COMBO CHARGER

WARNING

Charge only MILWAUKEE 12 and 

18V  Li-Ion  batteries  in  the 

MILWAUKEE 12 and 18V Li-Ion Combo Charger. 

Other types of batteries may cause personal in

-

jury and damage.

When to Charge the Battery Pack 

with this MILWAUKEE Charger

Remove the battery pack from the tool for charging 

when convenient for you and your job. MILWAUKEE 

batteries do not develop a "memory" when charged 

after only a partial discharge. It is not necessary to 

run down the battery pack before placing it on the 

charger. 

• Use the Fuel Gauge to determine when to charge 

your MILWAUKEE Li-Ion battery pack. 

• You can "Top-Off" your battery pack's charge before 

starting a big job or long day of use. 

• The only time it is necessary to charge the 

MILWAUKEE Li-Ion battery pack is when the battery 

pack has reached the end of its charge. To signal 

the end of charge, power to the tool will drop quickly, 

allowing you just enough power to finish making a 

cut, drilling a hole, or driving a fastener. Charge the 

battery pack as needed.

How to Charge the Battery Pack

Align  the  battery  pack  with  the  bay  and  slide  the 

battery pack into the charger as far as possible. The 

red light will come on, either flashing quickly (bat

-

tery pack is too hot or cold), flashing slowly (battery 

pack is waiting for another pack to finish charging) 

or continuous (pack is charging). 

• A fully discharged battery pack with an internal tem

-

perature in the normal range will charge in about 30 

to 185 minutes, depending on the battery pack. 

• Heavily cycled batteries may take longer to charge 

completely. 

• The Fuel Gauge lights on 18V battery packs are 

displayed as the pack is being charged, indicating 

how fully charged the pack is. The fuel gauge will 

turn off when charging is complete.

• After charging  is complete, the continuous  green 

light will come on.  

• The charger will keep the battery pack fully charged 

if it is left on the charger. The light indicator will flash 

green during this maintenance charging.

• The second pack inserted in the charger will begin 

charging when the first pack inserted is fully charged.

• If the light indicator flashes red and green, check that 

the battery pack is fully seated into the bay. Remove 

the battery pack and reinsert. If the light continues 

to flash red and green, the battery pack may be ex

-

tremely hot or cold, or wet. Allow the battery pack to 

cool down, warm up, or dry out and then reinsert. If 

the problem persists, contact a MILWAUKEE service 

facility.

• If the light indicator does not come on, check that 

the battery pack is fully seated into the bay.  Remove 

the battery pack and reinsert.  If the light indicator 

still does not come on, remove pack(s) and unplug 

charger  for  at  least  2  minutes.   After  2  minutes, 

plug charger back in and insert pack.  If after these 

attempts the light indicator still does not come on, 

contact a MILWAUKEE service facility.

Charging a Hot or Cold Battery Pack

The Red Flashing Indicator light on the charger in

-

dicates that the battery pack temperature is outside 

the charging range. Once the battery pack is within 

the acceptable range, normal charging will take place 

and the red light will be continuous. Hot or cold bat-

teries may take longer to charge.

Li-Ion Charging Status

Battery Pack 

Temperature

Red Charger 

Indicator Light

Charging Status

Too Hot

Normal Range

Too Cold

Fast Flashing

Continuous

Fast Flashing

Not charging

Normal charging

Not charging

Powering the Charger with an Inverter

or Generator

The charger will operate with most generators and 

inverters rated at 300 Watts or higher.

Maintenance and Storage

Store your charger in a cool, dry place. 

As  a  general  practice,  it  is  best  to  unplug  battery 

chargers and remove batteries when not in use. 

No battery pack damage will occur, however, if the 

charger and battery pack are left plugged in.

Repairs

The charger has no serviceable parts.

WARNING

To reduce the risk of injury, always 

unplug the charger and remove the 

battery from the charger before performing any 

maintenance. Never disassemble the battery or 

charger. Contact a MILWAUKEE service facility 

for ALL repairs.

To reduce the risk of injury and damage, never 

immerse your battery or charger in liquid or allow 

a liquid to flow inside them.

Cleaning

Clean out dust and debris from charger vents and 

electrical contacts by blowing with compressed air. 

Use only mild soap and a damp cloth to clean the 

battery pack and charger, keeping away from all elec

-

trical contacts. Certain cleaning agents and solvents 

are harmful to plastics and other insulated parts. 

Some of these include gasoline, turpentine, lacquer 

thinner, paint thinner, chlorinated cleaning solvents, 

ammonia and household detergents containing am-

monia. Never use flammable or combustible solvents 

around batteries, charger, or tools.

Repairs

The charger has no serviceable parts. 

Summary of Contents for 48-11-2401

Page 1: ...2401 48 11 2420 48 11 2430 Cat No No de cat 48 11 2402 48 11 2440 48 11 2460 Cat No No de cat 48 11 1815 48 11 1820 Cat No No de cat 48 11 1828 48 11 1840 48 11 1850 48 11 1860 48 11 1890 New batteri...

Page 2: ...eptacle 10 USE ONLY RECOMMENDED ATTACHMENTS Use of an attachment not recommended or sold by the battery charger or battery pack manufac turer may result in a risk of fire electric shock or personal in...

Page 3: ...lts 12 DC Battery Cat No 48 11 2420 Volts 12 DC Battery Cat No 48 11 2430 Volts 12 DC Battery Cat No 48 11 2440 Volts 12 DC Battery Cat No 48 11 2460 Volts 12 DC Operating Temperature Battery and Char...

Page 4: ...Rechargeable Battery Recycling Corporation RBRC At the end of your battery pack s useful life return the battery pack to a MILWAUKEE Branch Office Service Center or the participating retailer nearest...

Page 5: ...mely hot or cold or wet Allow the battery pack to cool down warm up or dry out and then reinsert If the problem persists contact a MILWAUKEE service facility If the light indicator does not come on ch...

Page 6: ...AN IMPLIED WAR RANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE This warranty ap...

Page 7: ...TO BE AS A CON SEQUENCE OF ANY DAMAGE TO FAILURE OF OR DEFECT IN ANY PRODUCT INCLUDING BUT NOT LIMITED TO ANY CLAIMS FOR LOSS OF PROFITS SOME STATES DO NOTALLOW THE EX CLUSION OR LIMITATION OF INCIDEN...

Page 8: ...ur dans un cordon de rallonge de calibre 16 ou plus poss dant des broches dont la quantit la taille et la forme sont quivalentes celles du chargeur Assurez vous que la rallonge est en bon tat 9 LE CHA...

Page 9: ...48 11 1890 Volts 18 CD Batterie au Li Ion No de Cat 48 11 2401 Volts 12 CD Batterie au Li Ion No de Cat 48 11 2402 Volts 12 CD Batterie au Li Ion No de Cat 48 11 2420 Volts 12 CD Batterie au Li Ion N...

Page 10: ...est tr s froid mettre le bloc des batteries sur l outil et utiliser celui ci pour une utilisa tion l g re Une alarme sonore peut se faire entendre pendant un court instant jusqu ce qu il se r chauffe...

Page 11: ...ge ne jamais plonger la batterie ou le chargeur dans un liquide et ne jamais laisser de l eau s y infiltrer Sceaux de recyclage pour pile RBRC Les sceaux de recyclage pour piles RBRC voir la Pictograp...

Page 12: ...i cela aura lieu pendant les 1 000 premi res charges ou les 2 premi res ann es de la garantie selon la premi re ch ance Cela signifie que pour les 1 000 premi res charges ou pendant les 2 premi res an...

Page 13: ...INT R TS PUNITIFS OU DE TOUTE D PENSE D HONORAIRES D AVOCATS DE FRAIS DE PERTE OU DE D LAISACCESSOIRES TOUT DOMMAGE D FAILLANCE OU D FAUT DE TOUT PRO DUIT Y COMPRIS NOTAMMENT LES PERTES DE PROFIT CER...

Page 14: ...l ctricas 9 EL CARGADOR ESTA ESPECIFICADO PARA 120 VOLTS CA SOLAMENTE Deber conectarse a un toma corriente adecuado 10 USE UNICAMENTE LOS ACCESORIOS RECO MENDADOS El uso de un accesorio no recomen dad...

Page 15: ...Cat No Bater a de Iones de litio 48 11 1815 Volts 18 CD Cat No Bater a de Iones de litio 48 11 1820 Volts 18 CD Cat No Bater a de Iones de litio 48 11 1828 Volts 18 CD Cat No Bater a de Iones de liti...

Page 16: ...MILWAUKEE de M18 est n dise ados para funcionar en temper aturas bajo cero Cuando el paquete de bater a se encuentre muy fr a col quela en una herramienta y utilice sta en una tarea ligera Es posible...

Page 17: ...e carga que tiene la bater a El indicador de combustible se apagar cuando la carga est completa El cargador mantendr la bater a completamente cargada si se deja en el cargador El indicador luminoso pa...

Page 18: ...arant a se aplica a los productos vendidos en los EE UU y Canad Consulte Service Center Search B squeda de centro de servicio en la secci n Parts Services Piezas y servicios del sitio web MILWAUKEE ww...

Page 19: ...STADOS NO PERMITEN LAEXCLUSI N O LIMITACI N DE RESPONSABILIDAD POR DA OS INCIDENTALES O EMERGENTES POR LO QUE LA ANTERIOR LIMITACI N O EXCLUSI N PODR A NO APLICARSE EN SU CASO ESTAGARANT AES EXCLUSIVA...

Page 20: ...58141815d7 961012063 01 A 05 16 Printed in China MILWAUKEE TOOL 13135 West Lisbon Road Brookfield Wisconsin U S A 53005...

Reviews: