background image

10

11

Press MIN/MAX to step through the minimum (MIN 

displayed), maximum (MAX displayed), and pres-

ent readings (both MAX and MIN are displayed).

To pause MIN MAX recording without erasing 

stored values, press HOLD button the HOLD is 

displayed.

To resume MIN MAX recording, press HOLD but-

ton again.

To exit and erase stored readings, press MAN/MAX 

button for two seconds or change the dial. 

Range Button

The DMM has both Manual and Autorange modes. 

In the Autorange mode, the DMM selects the range 

with the best resolution, and in the Manual Range 

mode, you override Autorange and select the range 

yourself. When you turn the DMM on, it defaults 

to Autorange and AUTO is displayed. To enter the 

Manual Range mode, press RANGE button, AUTO 

disappears. In the Manual Range mode, press 

RANGE button to increment the range. After the 

highest range, the Meter wraps to the lowest range. 

When in Manual mode and measuring current , if 

the value being measured is greater than 600mA 

and the user is set to a mA range, the tool will 

display an "OL" indicator and switch the user into 

the correct current range. To exit Manual Range, 

press RANGE button for two seconds or change 

the dial. The Meter returns to Autorange and AUTO 

is displayed. 

 CAUTION 

Pressing the MIN/MAX button without apply-

ing voltage disables the Auto-ranging func-

tion and 

fi

 xes the Range to 6mV. Connect the 

test leads to the circuit under test and press 

the MIN/MAX button after an appropriate 

range is selected by Auto-ranging function.

°F / °C

To switch between Fahrenheit or Celsius, press 

the °F / °C button.

Sleep Mode

The DMM is automatically powered off in about 20 

min after the last Rotary Dial or button operation. To 

reset, rotate the Rotary Dial to OFF. If the display 

is still blank when a new dial setting is selected, 

replace the batteries.

The DMM does use battery power in sleep mode. 

Be sure to switch the tool to OFF to conserve bat-

tery power.

Over-

fl

 ow indication

Any time the input exceeds the measuring range 

“OL” or “-OL” is displayed.

Accessory Bay

To install an accessory, slide it into the accessory 

bay on the back of the DMM. Follow the instructions 
supplied with the accessory

FIVE YEAR TOOL LIMITED 

WARRANTY

MILWAUKEE Test & Measurement Product (including 

bare tool, M12™ battery pack(s) and battery charger) 

is warranted to the original purchaser only to be free 

from defects in material and workmanship. Subject to 

certain exceptions, MILWAUKEE will repair or replace 

any part on this product which, after examination, is 

determined by MILWAUKEE to be defective in material 

or workmanship for a period of 

fi

 ve (5) years* after the 

date of purchase. Return of the Test & Measurement 

tool to the nearest Milwaukee Electric Tool Corporation 

- factory Service Center, freight prepaid and insured 

is required. A copy of the proof of purchase should be 

included with the return product. This warranty does not 

apply to damage that MILWAUKEE determines to be 

from repairs made or attempted by anyone other than 

MILWAUKEE authorized personnel, misuse, alterations, 

abuse, normal wear and tear, lack of maintenance, or 

accidents.

* See separate & distinct CORDLESS BATTERY PACK 

LIMITED WARRANTY statement for the warranty period 

of the LITHIUM-ION battery pack that ships with Test & 

Measurement Product. *Alkaline battery that ships with 

Test & Measurement Product is separately warranted 

by the alkaline battery manufacturer.

*The warranty period for a Voltage Detector with Work 

Light – 2201 20, Voltage Detector with LED – 2202-20 

or M12™ 2-Beam Plumb Laser – 2230 20 is one (1) 

year from the date of purchase.

Warranty Registration is not necessary to obtain the ap-

plicable warranty on MILWAUKEE product. The manu-

facturing date of the product will be used to determine 

the warranty period if no proof of purchase is provided 

at the time warranty service is requested.

ACCEPTANCE OF THE EXCLUSIVE REPAIR AND 

REPLACEMENT REMEDIES DESCRIBED HEREIN 

IS A CONDITION OF THE CONTRACT FOR THE 

PURCHASE OF EVERY MILWAUKEE PRODUCT. IF 

YOU DO NOT AGREE TO THIS CONDITION, YOU 

SHOULD NOT PURCHASE THE PRODUCT. IN NO 

EVENT SHALL MILWAUKEE BE LIABLE FOR ANY 

INCIDENTAL, SPECIAL, CONSEQUENTIAL OR PUNI-

TIVE DAMAGES, OR FOR ANY COSTS, ATTORNEY 

FEES, EXPENSES, LOSSES OR DELAYS ALLEGED 

TO BE AS A CONSEQUENCE OF ANY DAMAGE TO, 

FAILURE OF, OR DEFECT IN ANY PRODUCT IN-

CLUDING, BUT NOT LIMITED TO, ANY CLAIMS FOR 

LOSS OF PROFITS. SOME STATES DO NOT ALLOW 

THE EXCLUSION OR LIMITATION OF INCIDENTAL 

OR CONSEQUENTIAL DAMAGES, SO THE ABOVE 

LIMITATION OR EXCLUSION MAY NOT APPLY TO 

YOU. THIS WARRANTY IS EXCLUSIVE AND IN LIEU 

OF ALL OTHER WARRANTIES, WRITTEN OR ORAL. 

TO THE EXTENT PERMITTED BY LAW, MILWAUKEE 

DISCLAIMS ANY IMPLIED WARRANTIES, INCLUDING 

WITHOUT LIMITATION ANY IMPLIED WARRANTY OF 

MERCHANTABILITY OR FITNESS FOR A PARTICU-

LAR USE OR PURPOSE; TO THE EXTENT SUCH 

DISCLAIMER IS NOT PERMITTED BY LAW, SUCH 

IMPLIED WARRANTIES ARE LIMITED TO THE DURA-

TION OF THE APPLICABLE EXPRESS WARRANTY 

AS DESCRIBED ABOVE. SOME STATES DO NOT 

ALLOW LIMITATIONS ON HOW LONG AN IMPLIED 

WARRANTY LASTS, SO THE ABOVE LIMITATION 

MAY NOT APPLY TO YOU, THIS WARRANTY GIVES 

YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO 

HAVE OTHER RIGHTS WHICH VARY FROM STATE 

TO STATE.

This warranty applies to product sold in the U.S.A. and 

Canada only.

MAINTENANCE

WARNING 

To reduce the risk of per-

sonal injury and damage, never immerse your 

tool in liquid or allow a liquid to 

fl

 ow inside it.

WARNING 

To reduce the risk of injury, 

always remove the batteries from the tool 

before performing any maintenance. Never 

disassemble the tool. Contact a 

MILWAUKEE

 

service facility for ALL repairs.

Cleaning

Clean dust and debris from tool. Keep tool clean, dry 

and free of oil or grease. Use only mild soap and a 

damp cloth to clean the tool since certain cleaning 

agents and solvents are harmful to plastics and other 

insulated parts. Some of these include gasoline, 

turpentine, lacquer thinner, paint thinner, chlorinated 

cleaning solvents, ammonia and household deter-

gents containing ammonia. Never use 

fl

 ammable or 

combustible solvents around tools.

Repairs

For repairs, return the tool to the nearest service 

center listed on the back cover of this operator's 
manual.

Maintaining Tool 

Keep your tool in good repair by adopting a regular 

maintenance program. After six months to one year, 

depending on use, return the tool to 

a MILWAUKEE

 

service facility for repairs.

If the tool does not start or operate at full power 

with new batteries, clean the contacts on the battery 

door. If the tool still does not work properly, return 

the tool to a 

MILWAUKEE

 service facility for repairs.

ACCESSORIES

For a complete listing of accessories refer to your

 

MILWAUKEE 

Electric Tool catalog or go online 

to www.milwaukeetool.com. To obtain a catalog, 
contact your local distributor or service center.

WARNING 

Always remove batteries 

before changing or removing accessories. Only 

use accessories speci

fi

 cally recommended for 

this tool. Others may be hazardous. 

Summary of Contents for 2217-20

Page 1: ...R S MANUAL AFIN DE R DUIRE LE RISQUE DE BLESSURES L UTILISATEUR DOIT LIRE ET BIEN COMPRENDRE LE MANUEL DE L UTILISATEUR PARA REDUCIR EL RIESGO DE LESIONES EL USUARIO DEBE LEER Y ENTENDER EL MANUAL DEL...

Page 2: ...sintendedapplicationsorconditions Otherwise theinstru ment ssafetyfunctionsmaynotwork resultinginseriouspersonalinjuryandinstrumentdamage To reduce the risk of injury from shock and arc blasts always...

Page 3: ...8 Rotary Dial 9 Min Max button 10 Hold button 11 Accessory bay on back not shown 4 2 1 3 5 6 7 8 9 10 Maximum voltage between any terminal and earth ground 600 V Cat III Rated Temperature Operating 1...

Page 4: ...t and Lo z Additional Accuracy by Crest Factor C F Add 6 0 for C F 1 0 2 0 Add 7 0 for C F 2 0 2 5 Add 9 0 for C F 2 5 3 0 Max Crest Factor 1 6 for 6600 5000 digits 2 0 for 5000 3000 digits 3 0 for 30...

Page 5: ...ct the test leads in series with the circuit under test and then turn circuit power on The reading is displayed 1 Set the Dial to position 2 Connect the red test lead to the V terminal and the black t...

Page 6: ...ufacturer The warranty period for a Voltage Detector with Work Light 2201 20 Voltage Detector with LED 2202 20 or M12 2 Beam Plumb Laser 2230 20 is one 1 year from the date of purchase Warranty Regist...

Page 7: ...ET TOUTES LES INSTRUCTIONS Ne pas suivre l ensemble des avertissements et des instructions peut entra ner une lectrocution un incendie ou des blessures graves en plus d endommager le multim tre et l...

Page 8: ...es Inc tats Unis et Canada Cat III Classification des surtensions tran sitoires en fonction de la tension nominale de secteur par rapport la terre Fusible Ne pas jeter ce produit avec les ordures m na...

Page 9: ...s du condensa teur mis l essai 6 La lecture s affiche DANGER Pour viter une d charge lectrique Ne jamais prendre une mesure sur un circuit dont la tension efficace est sup rieure 600 V c a Ne pas uti...

Page 10: ...des utilisations incorrectes des alt rations des utilisations abusives une usure normale une carence d entretien ou les accidents Consulter les nonc s de la GARANTIE LIMIT E DES BLOCS PILES SANS FIL...

Page 11: ...fuente conocida antes de usar el instrumento o tomar alguna medida como resultado de la indicaci n proporcionada por el instrumento No instale piezas sustitutas reemplace los fusibles ni haga modific...

Page 12: ...ici n y que la funci n de retenci n de datos est des activada De lo contrario no puede efectuarse la medici n deseada Luz de fondo de la pantalla de cristal l quido La luz de fondo de la pantalla de c...

Page 13: ...ad con la tapa de las bater as fuera de su lugar Mantenga los dedos detr s de las protecciones y lejos de las puntas de los conductores de prueba cuando efect e una medici n Voltaje corr cont Medicion...

Page 14: ...aciones env e la herramienta al centro de servicio m s cercano que figure en la contraportada de este manual del operador Mantenimiento de la herramienta Mantenga su herramienta en buenas condiciones...

Page 15: ...I N A CLIENTES Av Presidente Mazarik 29 Piso 7 11570 Chapultepec Morales Miguel Hidalgo Distrito Federal Mexico Telefono 52 55 4160 3547 e mail servicio ttigroupna com Adicionalmente tenemos una red n...

Reviews: