background image

3

 

Maintain  labels  and  nameplates. 

These carry 

important information. If unreadable or missing, contact 

a MILWAUKEE service facility for a free replacement.

• 

WARNING

Some dust created by power sanding, 

sawing, grinding, drilling, and other 

construction activities contains chemicals known to 

cause cancer, birth defects or other reproductive harm. 

Some examples of these chemicals are:

• lead from lead-based paint

• crystalline silica from bricks and cement and other 

masonry products, and

• arsenic and chromium from chemically-treated lumber.

 Your risk from these exposures varies, depending on 

how often you do this type of work. To reduce your 

exposure to these chemicals: work in a well ventilated 

area, and work with approved safety equipment, such 

as those dust masks that are specially designed to 

filter out microscopic particles.

EXTENSION CORDS

Grounded tools require a three wire extension 

cord. Double insulated tools can use either a two 

or three wire extension cord. As the distance from 

the supply outlet increases, you must use a heavier 

gauge extension cord. Using extension cords with 

inadequately sized wire causes a serious drop in 

voltage, resulting in loss of power and possible tool 

damage. Refer to the table shown to determine the 

required minimum wire size.

The smaller the gauge number of the wire, the greater 

the capacity of the cord. For example, a 14 gauge 

cord can carry a higher current than a 16 gauge cord. 

When using more than one extension cord to make 

up the total length, be sure each cord contains at 

least the minimum wire size required. If you are using 

one extension cord for more than one tool, add the 

nameplate amperes and use the sum to determine 

the required minimum wire size.

Guidelines for Using Extension Cords

• If you are using an extension cord outdoors, be sure 

it is marked with the suffix “W-A” (“W” in Canada) 

to indicate that it is acceptable for outdoor use.

• Be sure your extension cord is properly wired 

and in good electrical condition. Always replace a 

damaged extension cord or have it repaired by a 

qualified person before using it.

• Protect your extension cords from sharp objects, 

excessive heat and damp or wet areas.

Recommended Minimum Wire Gauge

For Extension Cords*

Nameplate Amps

Extension Cord Length

25'

50'

75'

100'

150'

0 - 2.0

2.1 - 3.4

3.5 - 5.0

5.1 - 7.0

7.1 - 12.0

12.1 - 16.0

16.1 - 20.0

18

18

18

18

16

14

12

18

18

18

16

14

12

10

18

18

16

14

12

10

--

18

16

14

12

10

--

--

16

14

12

12

--

--

--

* Based on limiting the line voltage drop to five volts at 150% 

of the rated amperes.

GROUNDING

WARNING

Improperly connecting the ground-

ing wire can result in the risk of 

electric shock. Check with a qualified electrician 

if you are in doubt as to whether the outlet is 

properly grounded. Do not modify the plug pro-

vided with the tool. Never remove the grounding 

prong from the plug. Do not use the tool if the 

cord or plug is damaged. If damaged, have it 

repaired by a MILWAUKEE service facility before 

use.  If  the  plug  will  not  fit  the  outlet,  have  a 

proper outlet installed by a qualified electrician.

Grounded Tools (Three-Prong Plugs)

Tools  marked  “Grounding  Required”  have  a  three 

wire cord and three prong grounding plug. The plug 

must be connected to a properly grounded outlet 

(See  Figure A).  If  the  tool  should  electrically  mal

-

function or break down, grounding provides a low 

resistance path to carry electricity away from the 

user, reducing the risk of electric shock.

The grounding prong in the plug is connected through 

the green wire inside the cord to the grounding 

system in the tool. The green wire in the cord must 

be the only wire connected to the tool's grounding 

system and must never be attached to an electrically 

“live” terminal.

Your tool must be plugged into an appro-

Fig. A

priate outlet, properly installed and 

grounded in accordance with all codes 

and ordinances. The plug and outlet 

should look like those in Figure A.

Double Insulated Tools (Two-Prong Plugs)

Tools marked “Double Insulated” do not require 

grounding. They  have  a  special  double  insulation 

system  which  satisfies  OSHA  requirements  and 

complies with the applicable standards 

Fig. B Fig. C

of Underwriters Laboratories, Inc., the 

Canadian Standard Association and 

the National Electrical Code. Double 

Insulated tools may be used in either 

of the 120 volt outlets shown in Figures 

B and C. 

SYMBOLOGY

 

  Double Insulated

 

  

Volts

 

 

Alternating Current

 

  

Amps

 

  No Load Revolutions per Minute (RPM)

 

BPM

  Blows per Minute Under Load (BPM)

 

C

US

  UL Listing for Canada and U.S.

 

 

Approval Mark for Mexico

SPECIFICATIONS

Cat. No. ..................................................... 5262-21

Volts

 .............................................................120 AC

Amps

 .....................................................................8

No Load RPM ............................................. 0 -1620

No Load BPM

 ............................................ 0 - 5860

Type

 .........................................................

SDS Plus

Carbide Tipped Percussion Bit (concrete)

 ........... 1"

Thin Wall Percussion Core Bit (concrete)

 ...... 2-1/2"

Twist Drill Bit (Wood) (Drill only)

 ....................1-1/8"

Twist Drill Bit (Steel) (Drill only)

 ........................ 1/2"

Summary of Contents for 1 Inch SDS PLUS

Page 1: ...of injury user must read and understand operator s manual AVERTISSEMENT Afin de r duire le risque de blessures l utilisateur doit lire et bien comprendre le manuel ADVERTENCIAPara reducir el riesgo de...

Page 2: ...tuations Dress properly Do not wear loose clothing or jewelry Keep your hair and clothing away from moving parts Loose clothes jewelry or long hair can be caught in moving parts If devices are provide...

Page 3: ...0 0 2 0 2 1 3 4 3 5 5 0 5 1 7 0 7 1 12 0 12 1 16 0 16 1 20 0 18 18 18 18 16 14 12 18 18 18 16 14 12 10 18 18 16 14 12 10 18 16 14 12 10 16 14 12 12 Based on limiting the line voltage drop to five volt...

Page 4: ...Push to RIGHT Starting Stopping and Controlling Speed 1 To start the tool grasp the handle firmly and pull the trigger 2 To vary the speed increase or decrease the pres sure on the trigger The further...

Page 5: ...to one year depending on use return the tool to a MILWAUKEE service facility for inspection WARNING To reduce the risk of personal in jury electric shock and damage never immerse your tool in liquid...

Page 6: ...his warranty is not valid in the following situations a When the product is used in a different manner from the end user guide or instruction manual b When the conditions of use are not normal c When...

Page 7: ...squent moins de se bloquer et sont plus faciles contr ler Utiliser l outil lectrique les accessoires les embouts etc conform ment ces instructions en tenant compte des conditions de travail et de la t...

Page 8: ...ENT Si le fil de mise la terre est incorrectement rac cord il peut en r sulter des risques de choc lectrique Si vous n tes pas certain que la prise dont vous vous servez est correctement mise la terre...

Page 9: ...t enlevez la pi ce N B Soyez prudent lorsque vous maniez des forets ou des ciseaux br lants MANIEMENT AVERTISSEMENT Pourminimiserlesrisques de blessures d branchez toujours l outil avant d y faire des...

Page 10: ...ement l outil et appuyez sur la g chette 5 Apr s avoir perc environ jusqu la profondeur des dents du foret enlevez la broche centrale et la plaque de guidage du foret Reprenez le per age 6 Lorsque vou...

Page 11: ...T PROVINCES NE PERMETTANT PAS DE LIMITATION DE DUR E DES GARANTIES IMPLICITES LES RESTRICTIONS CI DESSUS PEUVENT DONC NE PAS VOUS TREAPPLICABLES LAPR SEN TE VOUS CONF RE DES DROITS L GAUX PARTICULIERS...

Page 12: ...aga Cualquier herramienta el ctrica que no pueda controlarse con el interruptor es peligrosa y debe repararse Desconecte el enchufe de la fuente de energ a y o quite la bater a de la herramienta el ct...

Page 13: ...a tierra Enchufes de tres clavijas Las herramientas marcadas con la frase Se requi ere conexi n de puesta a tierra tienen un cable de tres hilo y enchufes de conexi n de puesta a tierra de tres clavij...

Page 14: ...la palanca de fijaci n ADVERTENCIA Para reducir el riesgo de le siones no agarre la broca mientras el mandril est girando o mientras que est cayendo la broca del portabrocas Colocaci n de las brocas...

Page 15: ...Si esto ocurre detenga la herramienta libere la broca y comience de nuevo Uso de tr panos Los tr panos son convenientes para taladrar orificios de mayor tama o para conductos y tuber as Los tr panos...

Page 16: ...LED para la Luz de trabajo es por la vida del producto sujeto a las limitaciones anteriores Si durante el uso normal el LED o Bulbo de LED falla la parte ser reemplazada sin cargo No se requiere el r...

Reviews: