BMP810002/81073A
AIR OPERATED VACUUM PUMP FOR DOOR SEALS
MILNOR Rapid load door seals are now deflated with an air operated vacuum pump. The air
operated vacuum pump quickly deflates the door seals when the stop button is pressed. Once the
stop button is pressed a timer in the door circuit prevents the doors from being opened for 7-1/2
seconds. This allows the seals time to deflate before the doors are open. The air operated
vacuum pump is mounted on the side of the main valve set. The two valves, the relay and the
time delay for the vacuum pump is shown on the wiring diagram that was shipped with the
machine. The two valves that operate the vacuum pump are labeled deflator enable and deflator
supply valve, the relay is aux 3-wire and the time delay is door latch delay.
Summary of Contents for 72044 WP2
Page 6: ......
Page 8: ......
Page 23: ...Section 1 Service and Maintenance ...
Page 40: ......
Page 42: ......
Page 43: ......
Page 44: ......
Page 64: ......
Page 65: ...Section 2 Shell and Door Assemblies ...
Page 70: ......
Page 72: ......
Page 76: ......
Page 79: ...Section 3 Drive Assemblies ...
Page 90: ......
Page 93: ......
Page 99: ......
Page 100: ......
Page 103: ......
Page 110: ......
Page 111: ...Section 4 Bearing Assemblies ...
Page 122: ......
Page 124: ......
Page 125: ...Section 5 Frame Pivots and Suspension ...
Page 126: ......
Page 134: ......
Page 138: ......
Page 140: ......
Page 143: ......
Page 146: ......
Page 147: ...Section 6 Control and Sensing Devices ...
Page 150: ......
Page 153: ...Section 7 Chemical Supply Devices ...
Page 156: ......
Page 158: ......
Page 159: ...Section 8 Water and Steam Piping and Assemblies ...
Page 160: ......
Page 169: ......
Page 173: ......
Page 178: ......
Page 179: ...Section 9 Pneumatic Piping and Assemblies ...
Page 183: ......
Page 184: ......
Page 185: ......
Page 188: ......
Page 195: ......