OM-196 188 Page 76
SECTION 8 – INTRODUCTION TO PROGRAMMING
The interface unit is designed for
use in pulse MIG welding (adaptive
or standard), or MIG welding.
The unit is factory-equipped with
eight programs for pulse MIG
welding.
The unit also provides memory for
the creation of up to eight MIG
programs (see Section 11).
The weld programs require the user
to enter information specific to the
welding application. This
information is entered as a part of
program development (see Section
9 for pulsed MIG information), and
during setup (see Section 14).
The eight pulse programs are
shown in the table. Each program
can be used in standard pulse MIG
or adaptive pulse MIG.
In an adaptive pulse MIG program,
the unit manipulates certain weld
variables to hold arc voltage
constant. This feature is described
in Section 10-5.
The factory-set parameters for
each program can be changed to
customize them for an application
(see Section 10).
8-1.
Pulse MIG Programs
Program
1
2
3
4
5
6
Hardwire Selected
.035” Steel, Argon – Oxy
.045” Steel, Argon – Oxy
.035” Steel, Argon – CO2
.045” Steel, Argon – CO2
.035” 309, Argon – CO2
.045” Steel, 309, Argon – CO2
7
3/64” 5356, Argon
8
.035” SIB, Argon
Softwire Selected
.045” Steel, Argon – Oxy
.035” 4043, Argon
.045” Steel, Argon – CO2
1/16” 4043, Argon
.
Selecting hardwire or softwire is
done during setup (see Section 14)
.045” 4043, Argon
.045” 5356, Argon
.035” 5356, Argon
1/16” 5356, Argon
8-2.
Standard Pulse Welding Programs
The following sixteen (16) pulse welding programs are in the control memory. Use this information if it is necessary to
change a standard program, or as a basis to build your own custom program. If at any time while changing a standard
program, or while building your own custom program, you want to go back to the standard program in the control
memory, see Section 14-12 for System memory Reset instructions. See Section 10 for explanation of Pulse welding
settings.
Apk = Peak Amperage, Abk = Background Amperage, PPS = Pulses Per Second, PWms = Pulse Width (millisec-
onds), Vpk = Peak Voltage
Summary of Contents for Auto Invision II
Page 41: ...OM 196 188 Page 35 Notes ...
Page 43: ...OM 196 188 Page 37 203 505 A ...
Page 44: ...OM 196 188 Page 38 Figure 6 2 Circuit Diagram For Control Board PC1 Part 1 of 3 ...
Page 45: ...OM 196 188 Page 39 203 311 1 of 3 ...
Page 46: ...OM 196 188 Page 40 Figure 6 3 Circuit Diagram For Control Board PC1 Part 2 of 3 ...
Page 47: ...OM 196 188 Page 41 203 311 2 of 3 ...
Page 48: ...OM 196 188 Page 42 Figure 6 4 Circuit Diagram For Control Board PC1 Part 3 of 3 ...
Page 49: ...OM 196 188 Page 43 203 311 3 of 3 ...
Page 50: ...OM 196 188 Page 44 Figure 6 5 Circuit Diagram For Function Meter Board PC3 ...
Page 51: ...OM 196 188 Page 45 190 696 ...
Page 53: ...OM 196 188 Page 47 Notes ...
Page 54: ...OM 196 188 Page 48 Figure 6 8 Circuit Diagram For Interface Module ...
Page 55: ...OM 196 188 Page 49 193 709 A ...
Page 56: ...OM 196 188 Page 50 Figure 6 9 Circuit Diagram For Microprocessor Board PC11 ...
Page 57: ...OM 196 188 Page 51 191 838 ...
Page 58: ...OM 196 188 Page 52 Figure 6 10 Circuit Diagram For Motor Board PC13 ...
Page 59: ...OM 196 188 Page 53 212 354 A ...
Page 60: ...OM 196 188 Page 54 Figure 6 11 Circuit Diagram For Switch Board PC15 182 996 ...
Page 61: ...OM 196 188 Page 55 200 739 Figure 6 12 Circuit Diagram For Junction Board PC16 ...
Page 62: ...OM 196 188 Page 56 Figure 6 13 Circuit Diagram For Interface Board PC12 Part 1 of 2 ...
Page 63: ...OM 196 188 Page 57 191 843 A Part 1 of 2 ...
Page 64: ...OM 196 188 Page 58 Figure 6 14 Circuit Diagram For Interface Board PC12 Part 2 of 2 ...
Page 65: ...OM 196 188 Page 59 191 843 A Part 2 of 2 ...
Page 66: ...OM 196 188 Page 60 Figure 6 15 Circuit Diagram For Customer Interface Board PC14 Part 1 of 3 ...
Page 67: ...OM 196 188 Page 61 Pensar 86147s03 Part 1 of 3 ...
Page 68: ...OM 196 188 Page 62 Figure 6 16 Circuit Diagram For Customer Interface Board PC14 Part 2 of 3 ...
Page 69: ...OM 196 188 Page 63 Pensar 86147s03 Part 2 of 3 ...
Page 70: ...OM 196 188 Page 64 Figure 6 17 Circuit Diagram For Customer Interface Board PC14 Part 3 of 3 ...
Page 71: ...OM 196 188 Page 65 Pensar 86147s03 Part 3 of 3 ...
Page 72: ...OM 196 188 Page 66 Figure 6 18 Circuit Diagram For Touch Sensor Board PC18 174 578 A ...
Page 73: ...OM 196 188 Page 67 200 739 A Figure 6 19 Circuit Diagram For Setup Pendant ...
Page 75: ...OM 196 188 Page 69 191 531 Figure 6 21 Circuit Diagram For Power Distribution Board PC20 ...
Page 80: ...OM 196 188 Page 74 Notes ...
Page 81: ...Auto Invision II OM 196 188K July 2003 Programming Instructions for ...
Page 130: ......