Cleaning and care
29
Replacing the condenser unit
Push the condenser unit back into
the housing as far as it will go.
Turn the lever down to the horizontal
position, making sure that the hook
on the lever clicks into the groove at
the bottom.
When replacing the inner cover after
cleaning, ensure that the rubber seal
fits correctly into the groove.
Otherwise water may leak from the
system.
Replace the inner cover making sure
the hooks are at the bottom. Hold it
at an angle and push down gently.
Press against the cover and lock it
with the lever.
The lever will be in the horizontal
position when locked.
Replace the service panel and press
the upper edge until it clicks into
position.
It is important to ensure that
both the condenser unit and the
cover are correctly positioned and
locked, otherwise water may leak
from the system.