Supervisor level
86
Automatic dispensing
Automatic dispensing via an external
dispensing system can be activated
Factory default: Off
Peak load signal
The peak-load negotiation function
enables the washing machine to be
connected to an energy management
system. When a signal is registered,
the washing machine's heater is
switched off for a short period. The
washing machine may only be oper-
ated with a peak-load system if this
system is connected to the washing
machine via the Miele XCI box.
– No function (factory default)
– Peak load with 230 V
– Peak load with 0 V
Peak load prevention
The peak-load negotiation function
can be deactivated with disinfection
programmes. When a signal is re-
gistered, the washing machine's
heater is not switched off.
Factory default: Off
Alternating current
The time left display depends on the
electrical connection. If a single-phase
connection is used, the setting must
be switched to
No
.
Factory default: Yes
Heating
The heating can be switched off and
the Thermostop step is skipped. In ad-
dition, heater fault monitoring is deac-
tivated.
Factory default: On