MACHINE STATUS
REV.0.01_COD.650184_A4
Page 41
9.4
Power failure
In the event of a brief power failure while a program is running, the current wash phase is repeated
and the program continued.
9.5
Reset
In the event of a malfunction while a program is running, the door remains closed and locked. To
acknowledge the fault message, proceed as follows:
1.
Press STOP
and START
simultaneously and hold for 5 seconds.
2.
The display indicates the button combination.
3.
Press the
P2
button followed by the
P1
button
.
4.
The reset is complete. The machine is once again ready for operation and the door can be
opened.
Note:
If the fault persists, e.g., due to a defective component, the machine will remain locked.
If this is the case, contact Miele Service or an authorized service technician.