PROGRAMS
REV.0.01_COD.650184_A4
Page 34
Program
Button Application
AD rinse
Rinse with fully demineralized water (DI water, (ultra)pure water),
holding time: 3 minutes.
Drying
Additional drying after the end of a program.
Drain
For draining wash water, e.g., after a program cancellation.
Fill DOS1
Primes the detergent dispenser system after replenishing or
replacing the container.
Fill DOS2
Primes the additional liquid agent dispensing system after
replenishing or replacing the container.
Fill DOS3
Primes the neutralizing agent dispensing system after
replenishing or replacing the container.
Fill DOS4
Primes the additional liquid agent dispensing system after
replenishing or replacing the container.
8.1
Program blocks
Drain
Drains water from the wash cabinet.
Pre-rinse
A pre-rinse removes coarse stains and substances which may cause foaming.
Main wash
Depending on the wash items, cleaning generally occurs at temperatures between 45°C
and 93°C (113°F and 199°F) with the addition of appropriate detergent (process
chemicals).
Interim rinse
In the interim rinse stages, chemicals from the previous phases are rinsed off and
neutralized.
Final rinse
To avoid deposits on the wash items and to reduce process chemical residues, fully
demineralized water should preferably be used, if available, for the final rinse.
Drying
Adequate drying reduces the risk of corrosion through residual moisture on the wash
items.