Installation
*INSTALLATION*
93
Disconnecting from the mains
Risk of electric shock.
There is a risk of electric shock if the
appliance is connected to the mains
supply during repair or service work.
After disconnection, ensure the
appliance cannot be switched back
on by mistake.
To disconnect the appliance from the
mains power supply, do one of the
following depending on installation:
Safety fuses
Completely remove fuses.
Automatic circuit breakers
Press the (red) test button until the
middle (black) button springs out.
Built-in circuit breakers
Circuit breakers at least type B or C:
Switch the lever from 1 (on) to 0 (off).
Residual current device (RCD)
Switch the main switch from 1 (on) to
0 (off) or press the test button.
Mains connection cable
The hob must be connected to the
electrical supply with a special
connection cable, type H 05 VV-F (PVC
insulated) with a suitable diameter.
Please see wiring diagram for
connection.
See the data plate on the hob for the
correct voltage and frequency.
Replacing the mains connection
cable
Risk of electric shock.
Incorrect connection to the power
supply may result in an electric
shock.
The mains cable must only be
replaced by a qualified electrician.
When replacing the mains cable only
use cable type H 05 VV-F with a
suitable cross section. A suitable
connection cable is available from your
Miele dealer.
Summary of Contents for KMDA 7476 FL