Cleaning and care
58
Grease filter/extraction grille
The extraction grille and the reusable
metal grease filter in the vapour
extraction fan collect solid matter from
kitchen vapours (grease, dust, etc.) and
therefore prevent soiling of the
downdraft extractor. Accumulated
grease solidifies over a longer period of
time and makes cleaning more difficult.
The grease filter should therefore be
cleaned at least every 3–4 weeks.
Risk of fire due to soiled grease
filter.
Grease collected in the grease filter
can ignite.
Clean the grease filter regularly.
Removing the extraction grille
Risk of damage to the extraction
grille.
Pull the extraction grille vertically out
of the top of the KMDA.
Take hold of the extraction grille in the
centre of the bars.
Pull the extraction grille up vertically.
Removing the grease filter
Lift up the extraction grille.
Remove the grease filter carefully. Do
not let the grease filter tip over.
Pour out any liquid which has
collected at the bottom of the grease
filter.
Fitting the grease filter
The grease filter has a symbol on the
front. The arrow on this points to the
right or left.
Insert the grease filter so that the
arrow is pointing to the opening
inside the casing.