Problems with the ice maker
Issue
Possible fault
Solution
The ice cube maker
will not switch on.
The appliance is not
plugged in.
Check that the appliance
is connected to the power
supply.
The ice cube maker
is not producing any
ice cubes.
When the appliance is turned on for the very first time, it
can take up to 10 hours for the first ice cubes to drop
out of the ice cube maker and collect in the container.
The appliance is not turned
on.
Check that the appliance
is switched on.
The water supply line was
not primed (purged of air)
before the appliance was
used for the first time.
Contact Miele.
Check if:
– the ice cube maker is
switched on.
– the water supply line is
open.
– there are ice cubes stuck
together and blocking the
exit.
– the ice cube container is
in the right position.
– the freezer compartment
temperature is too high.
– the water pressure is too
low. The water pressure
must be between 25 and
80 psi (1.7-5.5 bar).
See "Ice Cube Maker"
and/or "Plumbing" for more
information.
Check whether the correct
water valve has been
installed.
Self-tapping valves and
3
/
16
" (4.76 mm) saddle
valves reduce the water
pressure and can block
the pipe.
Frequently asked questions
46