Technical details
179
Imperial
Metric
Height with machine lid
Height without machine lid
32 7/8"
32 5/16"
835
mm
820
mm
Width
35 3/8"
898
mm
Depth
Depth with door open
mm
mm
Wash cabinet dimensions:
Height
Width
Depth of upper basket/lower basket
20 9/16"
21 1/8"
20 9/16"
520
mm
530
mm
474
mm/
520
mm
Weight (net)
216
lbs
98
kg
Max. load capacity of open door
81.6
lbs
37
kg
Voltage, rated load, fuse rating
See data tag
See data tag
Power cord
Approx.
5' 9"
ft.
Approx.
1.8
m
Water connection water temperature:
Cold water/steam condenser
Hot water/DI water (optional)
max.
68
°F
max.
150
°F
Max.
20
°C
Max.
65
°C
Static water pressure
max.
145
psi
Max.
1,000
kPa pressure
Minimum water connection flow pressure:
Cold water/steam condenser
Hot water
DI water (optional)
14.5
psi
5.8
psi
4.4
psi
100
kPa pressure
40
kPa pressure
30
kPa pressure
Recommended water connection flow pressure:
Cold water/hot water
DI water (optional)
Steam condenser
29
psi
29
psi
14.5
psi
≥
200
kPa pressure
≥
200
kPa pressure
≥
100
kPa pressure
DI water supply without pressure (optional)
1.3-8.7
psi
8.5-60
kPa
Drain height
min.
11 3/4"
ft, max.
3' 3"
ft
Min.
0.3
m, max.
1.0
m
Drain hose length
max.
13' 1"
ft
Max.
4.0
m
Operation (according to IEC/EN 61010-1):
Ambient temperature
Relative humidity maximum
linear decrease to
Relative humidity minimum
40
°F to
104
°F
80 % for temperatures up to 88°F
50 % for temperatures up to 104°F
10%
5
°C to
40
°C
80% for temperatures up to 31°C
50% for temperatures up to 40°C
10%
Storage and transportation conditions:
Ambient temperature
Relative humidity
Air pressure
- 4
°F to
140
°F
10
% to
85
%
7.25
psi to
15.37
psi
- 20
°C to
60
°C
10
% to
85
%
500
hPa to
1060
hPa
Altitude above sea level (according to
IEC/EN 61010-1)
up to
6,561
ft*
Up to
2,000
m*
Type of protection (according to IEC 60529)
IP
20
Soiling level (according to IEC/EN 61010-1)
2
Overvoltage category (according to IEC 60664)
II
Sound emission values in dB (A),
sound pressure level LpA during cleaning and dry-
ing phases
<
70
Certifications
CAN/CSA-C22.2 No. 61010-1-04, CAN/CSA-C22.2 No. 61010-2-040, UL
Std. No. 61010-1 (2nd Edition), IEC 61010-2-040:2006
Manufacturer’s address
Miele & Cie. KG, Carl-Miele-Strasse 29,
33332 Gütersloh, Germany
* If installed above
6,561
ft (
2,000
m), the boiling point of the wash water will be lower. In this case, the disinfecting tempera-
ture and the holding time might need to be adjusted.