HYB-1000 KIT
5. The final instruction screen appears.
Instruction Screen 4
Avoid Hazardous Driving Conditions
The Drive Test will require you to rapidly acceler-
ate and decelerate the vehicle. Make sure you can
perform this test in a safe area without risking col-
lision with other traffic, vehicles or pedestrians.
Press NEXT to begin the Drive Test.
6. A Drive Test TESTING screen appears.
Drive Test TESTING Screen
As the test proceeds the bar graph will gradually fill from
left to right. Quicker acceleration and firmer braking will
increase the rate of data acquisition.
7. Once it has acquired enough data, the HYB-1000 tester
will emit a notification tone and display the test results on
the screen.
Interpreting The Test Results
Once a Drive Test has been successfully completed, the first of
two RESULTS screens appears.
1. The first RESULTS screen displays the Drive Test decision.
RESUlTS Screen 1
2. Use the
UP (
) or DOWN (
) ARROW keys to advance to
the second RESULTS screen.
State-of-health
graph
Display
Description
AVG BLK
77.0S
Average conductance per block
measured in Siemens.
AVG BLK
100%
Average State-Of-Health per block
AVG BLK
13.60V Average voltage per block
Δ BLK
8%
Percentage of conductance
change from the highest to
lowest block
AVG TEMP 57
˚
F
Average temperature per block
Δ TEMP
1
˚F
Amount of temperature change
from the highest to lowest block
RESUlTS Screen 2
3. Press the BACK key to return to the HYBRID TEST menu or
the PRINT key to send the test results to the (optional) IR
printer.
Drive Test Result Decisions
Display
Description
PACK OK
The tester has not detected
any errors and the vehicle
can be returned to service.
HYBRID BATTERY PACK
REQUIRES SERVICE!
PACK CONDUCTANCE LOW.
The HYB-1000 tester has
determined hybrid battery
pack state-of-health is
low and the pack requires
servicing.
HYBRID BATTERY PACK
REQUIRES SERVICE!
PACK OUT OF BALANCE.
The HYB-1000 tester
has determined hybrid
battery pack blocks are
not consistent with each
other and the pack requires
servicing.
HYBRID BATTERY PACK
REQUIRES SERVICE!
PACK CONDUCTANCE LOW
AND OUT OF BALANCE.
The HYB-1000 tester has
determined hybrid battery
pack state-of-health is low
and the blocks are not
consistent with each other.
The pack requires servicing.