HYB-1000 KIT

2. If no problems are found, the tester displays a battery pack

okay message.

No Trouble Codes Found

If any problems were found during the testing process, a 

listing of the Diagnostic Trouble Codes is displayed.

Diagnostic Trouble Codes

Each  displayed  code  indicates  a  problem  the  tester  has 

found.

3. To view the description and cause for each trouble code,

use the ARROW keys to select the desired Trouble Code

and  press  the  VIEW  soft  key  to  continue.   You  can  also

press the associated number key on the tester keypad to

go directly to the description.
A  description  of  the  Trouble  Code  is  displayed  on  the

screen.

Trouble Code Description

4. Use the UP (

) or DOWN (

ARROW keys to display the

cause of the Trouble Code (if available).

Trouble Code Cause

5. Press the BACK

 soft key to return to the TROUBLE CODES

screen.

Clear Trouble Codes

This function clears the TROUBLE CODES results from 

the vehicle’s onboard computer.

1. From the HYBRID TESTS menu, use the ARROW key to se-

lect the TROUBLE CODES icon and press the 

SELECT soft

key.

Hybrid Tests Menu

The TROUBLE CODES menu appears on the screen.

2. Using  the 

ARROW

  keys,  highlight  the  CLEAR  TROUBLE

CODES icon and press the SELECT soft key.

Highlighted Clear Trouble Code Icon

The tester will attempt to connect with the CVG-2 module.  

If the module is not connected, the tester will prompt you 

to turn the key on and connect the module at this time.

3. At the confirmation screen, press the YES soft key to clear

the codes.  The HYB-1000 tester will confirm that the codes

have been cleared.

Run Chart

The Run Chart function is designed to measure and 

graphically display the amperage moving in and out 

of the hybrid battery pack.  Voltage is also measured 

across the battery pack.

To perform an accurate test using the Run Chart, the vehicle 

must be driven while the tester displays the data.

NOTE: Always obey all traffic laws while performing 

this test.

1. From the HYBRID TESTS menu, select the RUN CHART icon

and press the SELECT soft key.

If the CVG-2 wireless convergence module has not been

connected to the OBD-II connector, the tester will prompt

you to connect it at this time.

Summary of Contents for HYB-1000

Page 1: ...INSTRUCTION ManuAl May 2010 167 000199B HYB 1000 Hybrid Battery System Analyzer For testing automotive hybrid battery packs and auxiliary lead acid batteries...

Page 2: ...shield when working with or around batteries Keep hair hands and clothing as well as the analyzer cords and cables away from moving engine parts Remove any jewelry or watches before you start servici...

Page 3: ...at uses live vehicle sensor information while performing an accelerated drive test The technician can print the results to an IR printer at the end of the test The large backlit graphical screen and i...

Page 4: ...aded data card slot for DTC code definitions test data storage and software upgrades DB 9 Connector Data Card Slot Connecting The Battery Test Cable Connect the battery test cable to the HYB 1000 hand...

Page 5: ...r on and off The analyzer also turns on automatically when you connect its test leads to a battery Title Bar The Title Bar shows you the name of the current menu test tool utility or function Selectio...

Page 6: ...ighlight it Highlighting changes the icon to a white picture on a black background To confirm your selection press the appropriate soft key Option Buttons Some lists have option buttons before each it...

Page 7: ...esults in its memory until you perform another test To review or print results before you retest select a test type in the Print View Menu Menu Icon Description Displays the last Battery and System Te...

Page 8: ...before the Main Menu is displayed The user selection screen is displayed when the unit is powered up for the first time 1 The first 4 user ID s are displayed on the screen when the tester is turned o...

Page 9: ...II Port This port is usually located on the drivers side of the vehicle underneath the dashboard Installed CVG 2 Module Once a successful connection has been made the blue status light at the end of...

Page 10: ...ICLE MODEL The models displayed on this screen will vary depending on the manufacturer selected on the previous screen The HYBRID TEST menu appears on the screen Hybrid Test Menu NOTE Make sure the HY...

Page 11: ...ROW key to se lect the TROUBLE CODES icon and press the SELECT soft key Hybrid Tests Menu The TROUBLE CODES menu appears on the screen 2 Using the ARROW keys highlight the CLEAR TROUBLE CODES icon and...

Page 12: ...e of temperature change across all the blocks within the pack The drive test requires the vehicle to repeatedly accelerate and decelerate until sufficient data has been collected The testing process w...

Page 13: ...n AVG BLK 77 0S Average conductance per block measured in Siemens AVG BLK 100 Average State Of Health per block AVG BLK 13 60V Average voltage per block BLK 8 Percentage of conductance change from the...

Page 14: ...properly install lead terminal adapt ers or using adapters that are dirty or worn may cause false test results To avoid damage never use a wrench to tighten the adapters more than turn At the start o...

Page 15: ...g Amps 3 MCA Marine Cranking Amps 4 JIS Japanese Industrial Standard 5 DIN Deutsch Industry Norm 6 SAE Society of Automotive Engineers 7 IEC International Electrotechnical Commission 8 EN European Nor...

Page 16: ...harge the battery before retesting may cause false readings If CHARGE RETEST appears again after you fully charge the battery replace the battery REPLACE BATTERY A REPLACE BATTERY result may also mean...

Page 17: ...o find the source of the noise fully charge the battery and retest If the message appears after recharging test the battery out of the vehicle Disconnect the battery cables and retest Unstable Battery...

Page 18: ...ther and the pack requires servicing HYBRID BATTERY PACK REQUIRES SERVICE PACK CONDUCTANCE LOW AND OUT OF BALANCE The HYB 1000 tester has determined hybrid battery pack state of health is low and the...

Page 19: ...TOTALS displays the total tests performed by User ID four IDs per screen User Totals Screen Totals by Decision The first screen displays the number of battery tests by decision The second screen displ...

Page 20: ...utility described in this section is listed in order by its icon title If you use the alphanumeric keypad to enter the number preceding the option button no additional keypress is needed to save or c...

Page 21: ...ntinue 3 To clear the default characters press the LEFT ARROW key To add a space move the cursor forward by pressing the RIGHT ARROW key ENTER USER ID USER01 4 Insert a character by pressing the alpha...

Page 22: ...D OPTIONS utility allows you to adjust the contrast of the text on the display and the backlight time Contrast Level The contrast level is 0 lightest to 10 darkest To change it 1 Press the UP or DOWN...

Page 23: ...with a maxi mum of 17 characters per line To create and edit a coupon see the procedure under Shop in this chapter for using the keypad to enter and backspace over characters Use the template to plan...

Page 24: ...rts on the top of the an alyzer and on the printer below the MODE button should be pointed directly at each other The maximum distance for reliable transmission between the ports is 17 in 45 cm To rea...

Page 25: ...isplay a warning message when the batteries need replacing Full Powered by test battery Decreasing Low Replacing the HYB 1000 Batteries 1 Turn the HYB 1000 face down 2 Remove the screw 3 Press gently...

Reviews: