Service manual
13. Troubleshooting
13.1 Indoor Unit Error Display
Display LED
STATUS
E0 EEPROM
error
E1
Indoor / outdoor units communication protection
E2
Zero-crossing examination error
E3
Fan speed beyond control
E5
Open or short circuit of outdoor temperature sensor
E6
Room temperature or evaporator temperature sensor open or short circuit of
P0 Module
protection
P1
Over voltage or too low voltage protection
P2
Compressor top protection against temperature
P3
Outdoor low temp. protection
P4
Inverter compressor drive error
Note: E4: Reserved function
13.1.1
Display LED
STATUS
E0
EEPROM parameter error
31
13.1.2 circuit or software error on indoor cortrol board
Display LED
STATUS
E1
Indoor / outdoor units communication protection
Circuit or software error on indoor control board
Replace the control board of indoor
Summary of Contents for MSV1-09HRDN1
Page 1: ...Cover MSV1 09HRDN1 MSV1 12HRDN1...
Page 4: ......
Page 11: ...Service manual 5 Refrigerant cycle diagram 7...
Page 14: ...Service manual 7 1 2 Indoor main PCB 10...
Page 15: ...Service manual 7 1 3 Outdoor main PCB 11...
Page 16: ...Service manual 7 1 4 Outdoor power PCB 12...
Page 17: ...Service manual 7 2 Wiring diagram 7 2 1 MSV1 09HRDN1 MSV1 12HRDN1 13...