![Midea MSV1-09HRDN1 Service Manual Download Page 18](http://html1.mh-extra.com/html/midea/msv1-09hrdn1/msv1-09hrdn1_service-manual_1790872018.webp)
Service manual
8. Installation
details
8.1
Wrench torque sheet for installation
Outside diameter
Torque
mm inch
Kg.m
φ
6.35
1/4 1.8
φ
9.52
3/8 4.2
φ
12.7
1/2 5.5
φ
15.88
5/8 6.6
φ
19.05
3/4 6.6
8.2
Connecting the cables
The power cord of connect should be selected according to the following specifications sheet.
Grade
Unit
7K 9K 12K
mm
2
1.0 1.0 1.5
8.3
Pipe length and the elevation
14
Pipe size
Capacity
Btu/h
GAS LIQUID
Standard
length
Max.
Max.
Additional
Elevation
Elevation
refrigerant
(m)
B (m)
B (m)
(g/m)
3/8’’ (
φ
9.52) 1/4’’
(
φ
6.35)
5 5 10 30
7k~12K
1/2’’ (
φ
12.7) 1/4’’
(
φ
6.35)
5 5 10 30
1/2’’ (
φ
12.7) 1/4’’
(
φ
6.35)
5 8 15 30
5/8’’ (
φ
15.88) 1/4’’
(
φ
6.35)
5 10 20 30
18K~28K
5/8’’ (
φ
15.88) 3/8’’
(
φ
9.52)
5 10 20 65
In case that
more than 5m.
Caution:
Capacity is base on standard length and maximum allowance length is base of reliability.
Oil trap should be install per 5-7 meters.
Summary of Contents for MSV1-09HRDN1
Page 1: ...Cover MSV1 09HRDN1 MSV1 12HRDN1...
Page 4: ......
Page 11: ...Service manual 5 Refrigerant cycle diagram 7...
Page 14: ...Service manual 7 1 2 Indoor main PCB 10...
Page 15: ...Service manual 7 1 3 Outdoor main PCB 11...
Page 16: ...Service manual 7 1 4 Outdoor power PCB 12...
Page 17: ...Service manual 7 2 Wiring diagram 7 2 1 MSV1 09HRDN1 MSV1 12HRDN1 13...