Service manual
29
11.12.3 Heating:
The set temperature decrease 1
℃
per hour. Two hours later, the set temperature will maintain as a
constant and the air circulation is kept at low speed (Cold air proof function takes precedence over all).
11.12.4 Auto:
The Sleep Mode running function operates in accordance with selected running mode by auto mode.
11.12.5
After 7 hours, unit cancels this modes automatically.
11.13. Auto restart function
In case of a sudden power failure, this function automatically sets the unit to previous settings before the
power failure when power returns.
11.14. Turbo function
The indoor fan will work in super high speed, the frequency of compressor will increase, the max run
time is 30 minutes. After 30 minutes, the unit will work in previous setting.