0.5 seconds later, after finishing the adjustment, the wired controller sends the information
of timer, the timer off and timer on setting are completed.
7) Cancel the Timer Setting
※
Push the TIME ON and TIME OFF, OK once more.
※
Adjust the time of timer on and timer off as 0.0 to cancel the timer on and timer off.
Notes: The time of timer on is the relative time; it is relative to the standard time of operating wired
controller. If having setting the timer on or timer off, then the clock cannot be adjusted.
8) Cancel the Filter Cleaning Icon
When the calculated operating time reach the setting filter cleaning time, the filter cleaning icon
will be lighted up, to remind the user to clean the filter screen. After cleaning it can long press the
ECONOMICIAL
button for 3 seconds to cancel the icon.
9) Initialization Parameters Setting
For some functions of the wired controller, if the default setting in following list cannot meet the
user’s request, the user can select the function for setting follow the below method.
First
code(Y)
First code function
Second code (X)
0
1
2
3
4
0
Cooling only/Cooling and
heating selection setting
Cooling and
heating (Default)
Cooling only
\
\
\
2
Power-off memory setting
Yes (Default)
No
\
\
\
3
Time setting for reminding
to clean the filter
Cancel the
function
1250 hours
2500 hours
(Default)
5000
hours
10000
hours
6
Centigrade/Fahrenheit
selection setting
Centigrade
(Default)
Fahrenheit
\
\
\
※
Long press the
FAN SPEED
and
MODE
buttons for 5 seconds together, and enter into the
initialization function setting interface.
※
After enter into the setting interface, the temperature display area will display
YX
. Y means
the first function code, and X means the second function code, details refer to the up table.
Y will on all the time, X will flash with 1Hz frequency.
※
Press
TEMP
▲
and
TEMP
▼
, to select the detail function under Y code, then press the
OK
key and the setting will work, and the system will automatically shift to next Y code
setting, until all the function codes have been set, then the system will quit the setting
interface automatically.
Summary of Contents for MONB-76C
Page 8: ...MCAC RTSM 201301 01 Midea R22 T1 side discharge duct manual 7 2 3 Unit structure...
Page 15: ...Midea R22 T1 side discharge duct manual MCAC RTSM 201301 01 12 MTA1 76CR MTA1 96CR...
Page 16: ...Midea R22 T1 side discharge duct manual MCAC UTSM 201301 01 11 MONB 76H MONB 96H...
Page 17: ...Midea R22 T1 side discharge duct manual MCAC RTSM 201301 01 12 MONB 76C MONB 96C...
Page 49: ...Midea R22 T1 side discharge duct manual MCAC RTSM 201301 01 38 System high pressure protection...
Page 55: ...Midea R22 T1 side discharge duct manual MCAC RTSM 201301 01 44 6 Exploded view MTA1 76HR...
Page 57: ...Midea R22 T1 side discharge duct manual MCAC RTSM 201301 01 46 MONB 76H...
Page 59: ...Midea R22 T1 side discharge duct manual MCAC RTSM 201301 01 48 MTA1 96HR...
Page 61: ...Midea R22 T1 side discharge duct manual MCAC RTSM 201301 01 50 MONB 96H...
Page 63: ...Midea R22 T1 side discharge duct manual MCAC RTSM 201301 01 52 MTA1 76CR...
Page 65: ...Midea R22 T1 side discharge duct manual MCAC RTSM 201301 01 54 MONB 76C...
Page 67: ...Midea R22 T1 side discharge duct manual MCAC RTSM 201301 01 56 MTA1 96CR...
Page 69: ...Midea R22 T1 side discharge duct manual MCAC RTSM 201301 01 58 MONB 96C...