II. X70G/X55G SERIES SPECIFICATIONS
RECOMMENDED MINIMUM CLEARANCES
Rear of Oven to Wall
Control end of Conveyor to Wall Non-control end of Conveyor to Wall
Domestic and std. export
6"
152mm
6"
152mm
6"
152mm
X70G/X55G SERIES OVEN SPECIFICATIONS
Dimensions
Single Oven
Double Oven
Triple Oven
Overall Height
43.25" (1,131mm)
56.27" (1,575mm)
68.31" (1,753mm)
Overall Depth
59.14" (1,690mm)
59.14" (1,690mm)
59.14" (1,690mm)
Overall Length
X70
106.1" (2,692mm)
106.1" (2,692mm)
106.1" (2,692mm)
X55
90.78" (2,305.8mm)
90.78" (2,305.8mm)
90.78" (2,305.8mm)
Conveyor Width
32" (813mm)
32" (813mm)
32" (813mm)
General Specifications
Weight
1,750lbs.(795kg)
3,500lbs. (1,589kg)
5,250lbs. (2,384kg)
Rated Heat Input (per oven cavity)
X70
160,000 BTU/Hr/Oven (168.8 MJ)
X55
140,000 BTU/Hr/Oven (147.7 MJ)
Maximum Operation
Temperature
600°F / 315°C
Air Blowers
Two blowers: 40 Hz Minimum and 90 Hz Maximum (see finger configuration)
Warm-up Time
20 minutes
X70G/X55G SERIES ELECTRICAL SPECIFICATIONS
Main Blower
Voltage
Control Circuit
Voltage
Phase
Frequency
Current Draw*
Poles
Wires
208-240VAC
24VDC
1
50/60 Hz
12 Amps
2
3 Wire (2 hot, 1 ground)
* The current draw ratings shown above are maximum values for normal operation, amperage draw will be less than the listed value.
NOTE:
Each oven includes a 6 ft cord with NEMA# L6-20P plug. Customer to provide NEMA# L6-20R receptacle.
X70G/X55G SERIES GAS SUPPLY SPECIFICATIONS
Gas Type
Inlet Pressure**
Manifold Pressure
Main Orifice Diameter**
Fixed Bypass Orifices**
Natural
X70
8-12" W.C.
(20-30 mbar)
3.5" W.C.
(8.7 mbar)
0.1654" (4.2mm) Dia.
P/N 77494
#46 Drill – 0.081" (2.057mm) Dia.
P/N
X55
8-12" W.C.
(20-30 mbar)
3.5" W.C.
(8.7 mbar)
#24 Drill – 0.152" (3.86mm) Dia.
P/N 76978
#46 Drill – 0.081" (2.057mm) Dia.
P/N
Propane
X70
8-12" W.C.
(20-30 mbar)
6.0" W.C.
(14.9 mbar)
#32 Drill – 0.116" (2.95mm) Dia.
P/N 77493
#53 Drill – 0.059" (1.49mm) Dia.
X55
8-12" W.C.
(20-30 mbar)
6.0" W.C.
(14.9 mbar)
#36 Drill – 0.1065" (2.7mm) Dia.
P/N 77272
#53 Drill – 0.059" (1.49mm) Dia.
** The gas supply pressures and orifice sizes shown are for ovens installed in North America. The required gas supply pressures and orifice sizes
of ovens installed in other locations are dependent on the local gas type and on all applicable local codes.
NOTE:
Wiring Diagrams are contained in Section 6 of this manual and are also located inside the oven at the bottom
of the Control Panel. Additional electrical information is provided on the oven’s serial plate.
This Manual Must Be Kept For Future Reference.
Summary of Contents for X55G Series
Page 8: ...SECTION 1 DESCRIPTION 8 NOTES...
Page 26: ...SECTION 2 INSTALLATION 26 Gas Train and Burner Assembly...
Page 37: ...SECTION 4 MAINTENANCE 37...
Page 38: ...SECTION 4 MAINTENANCE 38 NOTES...
Page 42: ...SECTION 6 ELECTRICAL SCHEMATICS 42...
Page 43: ...SECTION 6 ELECTRICAL SCHEMATICS 43 Wiring Diagram G208 240 AC 50 60 Hz X55 77605 REV B...
Page 44: ...SECTION 6 ELECTRICAL SCHEMATICS 44...