SECTION 3
OPERATION
29
previously used set temperature will appear when the
oven is turned ON again.
C. Adjusting the Belt Time
To adjust the belt time, press and hold the
button until the belt time display flashes. Press the
or
button until the desired belt time is
displayed. Press the
button to set and save the
new time value. If the
button is not pressed, the
new time will be present only until the oven is turned
OFF. The previously used belt time will appear when
the oven is turned ON again.
D. Daily Shutdown Procedure (Turning the Oven
Off)
To turn the oven OFF, turn the ON/OFF rotary switch
to the OFF position. If the oven is below 200°F cool
down temperature, then the display will go blank. If the
oven is above 200°F, the display will show “COOL
DOWN” and the blowers will run at a preset cool down
speed until the oven temperature fails below 200°F at
which point the oven will go to the OFF mode. In the
OFF mode, the screen will display the “WOW OVEN”
screen for a one minute period after which the screen
backlight will shut off. The oven will stay in this
condition until it is started again, with no outputs
energized.
III. PROGRAMMING INSTRUCTIONS
(MANAGERS MODE)
A. Changing Baking Blower Speeds (Run Mode)
To change the ENTRANCE and/or EXIT blower
speeds without turning the oven OFF:
1. Enter the BLOWER CONFIGURATION Screen.
Press and hold
key until “PASSWORD”
appears on the screen. Press
and
. The screen should
appear as below.
2. Press
until LEFT HIGH HZ is flashing.
Press
to change LEFT HIGH HZ. Press
or
to display the desired value.
Press
to accept the new value. Follow same
procedure for the RIGHT HIGH HZ value if
required.
−
MINIMUM HZ VALUE: 40 Hz
−
MAXIMUM HZ VALUE: 90 Hz
B. Changing Energy Mode Status (Run Mode)
If the photo eye should ever fail to operate, baking
mode can be continually engaged by disabling the
energy mode. A service call should be made in the
interim, as energy use will be considerably higher
without the energy mode.
Press
until ENERGY MODE is flashing. Press
. Status of energy mode will be flashing (i.e.,
YES or NO). Press
to change status to desired
state. Press
to accept status change. Press
to leave the BLOWER CONFIGURATION
screen.
Summary of Contents for X55G Series
Page 8: ...SECTION 1 DESCRIPTION 8 NOTES...
Page 26: ...SECTION 2 INSTALLATION 26 Gas Train and Burner Assembly...
Page 37: ...SECTION 4 MAINTENANCE 37...
Page 38: ...SECTION 4 MAINTENANCE 38 NOTES...
Page 42: ...SECTION 6 ELECTRICAL SCHEMATICS 42...
Page 43: ...SECTION 6 ELECTRICAL SCHEMATICS 43 Wiring Diagram G208 240 AC 50 60 Hz X55 77605 REV B...
Page 44: ...SECTION 6 ELECTRICAL SCHEMATICS 44...