DOC 6501_Release V
ATS-6501 Users Guide
104
6.2.2 Outputs Enabled
This indicator will turn off if the ATS-6501 detects a hardware fault with one or more of the
output modules. Verify the output modules are locked to reference and the outputs are enabled
using the
status health:outputs_disabled
command and verify both active and occurrences = 0.
ATS-6501>status health:outputs_disabled
[active] false
[cleared]
[what] Outputs are enabled
[when] 2013-08-06-20:51:14.207
[occurrences] 0
[set]
[what] Outputs are disabled
[when] 2013-08-05-14:25:56.817
[OK] 2013-08-08T14:41:32Z
Users can determine which output module(s) has failed:
•
Based on which systems the ATS-6501 is driving are no longer operating properly
•
By unplugging the output modules, one at a time, to see which output module was at
fault.
Note
: If this does not work there may be more than one output module that failed. Pull
them all and reinsert them one at time to see which one(s) cause a FAULT.
•
By using the
status health:output_modules
command and/or the
syslog
command and
checking both the active = true and/or occurrences is greater than 0.
ATS-6501>status health:output_modules
[1]
[active] false
[occurrences] 0
[ports]
[1]
[active] false
[occurrences] 0
[2]
[active] false
[occurrences] 0
[3]
[active] false
[occurrences] 0
[4]
[active] false
[occurrences] 0
[2]
[active] false
[occurrences] 0
[ports]
[1]
[active] false
[occurrences] 0
[2]
[active] false
[occurrences] 0
[3]