DOC 6501_Release V
ATS-6501 Users Guide
77
Users can further refine the requested data fields by adding the desired information line to the
field to look for specific data. If the user wanted to look for the system uptime, the user would
simply add a “:” then the sub-category under unit. Additional subcategories can be added to the
command line, separated with the “:”.
ATS 6501>>status unit
:
uptime
3 days, 4 hours, 42 minutes
[OK] 2013-08-07T20:41:43Z
ATS-6501>status health:fan:1
[active] false
[occurrences] 0
[OK] 2013-08-07T20:41:57Z
3.7 GPS Data Logging (Not available on SAASM Type I)
Certain applications require that GPS data be retrieved in a timely manner. There are two
available options for this purpose.
•
FTP Data Logging
•
Real Time Data
3.7.1 FTP Data Logging
Data can be recorded and stored on the ATS-6501 and can be retrieved via a FTP client
(username: ftp, password: ftp). The logs that are stored are determined by the user and can be one
of any of the ASCII logs specified in the Novatel OEMV user manual. To set up data logging
users will need to follow the steps outlined below to set up the type of data to be logged, log file
intervals, maximum number of log files to store, set up the filename schema, set the file
compression on or off, and then turn the logging on. Users can also verify the data logging
configuration settings.
The OEMV user manual is at: (
http://www.novatel.com/support/docupdates.htm#oemv
)
A.
Access the system via the command port.
B.
Use the
log ftp <novalog>
command to set up they data type to be sent over the data port.
The
novalog
text on the command line specifies which data type to forward over this
port. Some examples are provided below.
ATS-6501> log ftp timea ontime 1
ionutca onchanged
// log IONO & UTC data
rawalma onchanged
// log almanac on startup
rangea ontime 60
// L1/L2 observations @ 60 seconds
C.
Set the interval for the log file to the desired value using the
log_interval
command. Log
interval value is in minutes and can be between 1 and 30 minutes. Default is 15 minutes.
ATS-6501>log_interval 15
[OK] 2013-08-07T20:43:00Z