DOC 6501_Release V
ATS-6501 Users Guide
19
The system will generate an error message if the operator attempts to enter an
unsupported or invalid code.
To verify the settings use the
settings hardware:slots:N
command (where N=Slot #) to
obtain the current settings for a particular card.
ATS-6501> settings hardware:slots:1
[tsc4373]
[ports]
[1]
[pps_period] 1.00000000000
[pps_width] 1.000000000000000e-04
[type] pps
[2]
[pps_period] 1.000000000000000e-06
[pps_width] 5.000000000000000e-07
[type] pps
[3]
[format] A
[signal_word] 3
[type] irig
[4]
[format] B
[signal_word] 0
[type] irig
[OK] 2013-08-05T16:02:45Z
Note:
The system will drop the leading Zeros in the signal_word.
To verify the card is working properly use the
status hardware:outputs:slots:N
command
(where N=Slot #) to obtain the current settings for a particular card.
ATS-6501>status hardware:outputs:slots:1
[ports]
[1]
[status] good
[2]
[status] good
[3]
[status] good
[4]
[status] good
[power] enabled
[type] 4394A
[OK] 2013-08-05T16:03:59Z
Warning:
The user configuration for the specific output formats are stored on the
system itself. Replacement modules will automatically be configured with the correct
output format as long as the replacement card is installed in the same slot. Moving the
output module to a different slot causes the system to configure the module with the
default output format(s) until that card slot is properly configured by the user.
2.4.2.2 4376A RS-422 PPS
The factory default for this module provides four 1PPS outputs. Users can change the PPS signal
parameters, on individual signal outputs.