![Microscan Visionscape HE1600T Getting Started Download Page 63](http://html.mh-extra.com/html/microscan/visionscape-he1600t/visionscape-he1600t_getting-started_1788342063.webp)
Advanced Example Using Multiple Tools
The 1600T in Action -
Ad
v
a
nced Example
3
v3.7.3, Mar 2009
Getting Started With Visionscape® Smart Camera
3-7
26.
Highlight
Snapshot
in the Step Tree (left pane). Right click
Snapshot
and
click
Insert Into
. FrontRunner™ displays the Insert Step window. Click the
Analysis Tools tab. Double click on TwoPt Locator to insert it into the
Snapshot.
27.
Highlight
TwoPt Locator
in the Step Tree (left pane). Right click
TwoPt
Locator
and click
Insert Into
. FrontRunner™ displays the Insert Step
window. Double click on Blob Tool to insert it into the TwoPt Locator.
28.
Right click on the Blob Filter and select
Delete
. Click
yes
to confirm the
deletion of the Blob Filter.
When you are finished, the Job should look like the Job in Figure 3–4.
FIGURE 3–4.
Step Tree
29.
Highlight Left Top IntersectLines Meas in the Step Tree (left pane).
30.
To select the reference for First Line, click in the area to the right of the blue
arrow (Figure 3–5), and click on the three dots, which displays the Select
Reference window, as shown in Figure 3–6.