Chapter 4
Operational Commands
4-6
MS-610 Scanner User’s Manual
4–
O
per
ati
ons.
downloaded at any time, and can be saved in nonvolatile memory with a <Z>
command. A stored master label will not affect standard operation unless
Match Code option is enabled.
The Xs denote alphanumeric data, from 1 to 31 characters.
<)> Request Master Label Information.
Immediately sends the master label
information to the host. To prevent conflicts with outputting label data, first send
the <I> command (Disable Laser Scanning (Laser Off)).
Note:
If the master label information has previously been stored in nonvolatile
RAM (by a <Z> command), cycling the power will restore that information.
<))> Delete Master Label Information.
Deletes master label information that
has previously been loaded by either <)XXXX)> Download Master Label Infor-
mation Command or <G> Store Next Label as Master Label command.