Operations Commands
MS-610 Scanner User’s Manual
3-9
3–Ser
ial
Conf
ig.
Example:
To define the Serial Trigger Character as a lowercase c, enter
<Kic>
.
External Trigger Level
Format:
<
Kj
external trigger level>
Example:
To change External Trigger Level to Negative, enter
<Kj0>
.
Noread Message
Format:
<
Kk
status,message>
Example:
To enable Noread Message and send the message “FAIL,” enter
<Kk1,FAIL>
.
Bar Code Output
Format:
<
Kl
status,when to output>
Example:
To set When to Output to End of Read Cycle, enter
<Kl3,1>
.
Good Decode Reads
Format:
<
Km
number of reads>
Example:
To change Good Decode Reads to 3, enter
<Km3>
.
Match Code
Format:
<
Kn
status>
Example:
To enable Match Code, enter
<Kn1>
.
external trigger level (initiates a read cycle):
0 = Negative
1 = Positive
status:
0 = Disabled
1 = Enabled
message:
Any ASCII string up to 7 digits. Default is
NOREAD
.
status:
0 = Disabled
1 = Enabled
when to output:
0 = As Soon As Possible
1 = End of Read Cycle
number of reads (before a good decode):
Any number from 1 to 31.
Default is
1
.
status:
0 = Disabled
1 = Enabled