Chapter 2
Menu Configuration
2-10
MS-610 Scanner User’s Manual
2–Menu Conf
ig.
Data Bits
Default:
Seven
Options:
Seven, Eight
Allows you to establish the total number of bits in each character.
RS-422
Default:
Disabled
Options:
Disabled, Enabled
Used only in Point-to-Point protocol, and not with RTS or CTS.
Whenever RS-422 is disabled, RS-232 is enabled in the background. How-
ever, an exception occurs whenever Multidrop has been selected. In this
case the functioning protocol will be RS-485 regardless of the displayed
status of RS-422 in the menus.