SOLID F166 HD User Manual
5-8
Code Descriptions
Check Point
Countermeasure
1F
Flash failure
Flash power supply AC IN
voltage is normal.
Check AC power source.
Flash power supply AC IN
voltage is not normal.
Call service engineer.
20
Fuser unit overheat
Fuser unit is not properly set.
Set the fuser unit properly.
Fuser unit exit blower is stopped
or the rotation speed of the
blower is too low.
Call service engineer.
Fuser unit cooling fan is stopped. Call service engineer.
22
Developing motor failure
(Abnormal rotation speed)
Turn the POWER switch ON. The
developing motor does not
operate or is not normal at the
proper timing during the
power-on initialization process.
Call service engineer.
23
Developing unit set
incorrectly
The developing unit is not
properly set.
Set the developing unit
properly.
The developing unit is properly
set.
Call service engineer.
24
Cleaner unit set
incorrectly
The green lock lever of the
cleaning unit is set at the “OPEN”
position.
Turn the green lock lever of
the cleaning unit to the
“LOCK” position.
The green lock lever of the
cleaning unit is set at the
“LOCK” position.
Call service engineer.
25
No Transfer-Charger
Transfer charger is not set.
Set the transfer charger.
Transfer charger is set.
Call service engineer.
26
No cleaning unit
Cleaning unit is not set.
Set the cleaning unit.
Cleaning unit is set.
Call service engineer.
28
Waste toner box full
Waste toner in the waste toner
box reaches the full level.
Replace the waste toner box.
Waste toner in the waste toner
box does not reach the full level.
Clean the waste toner full
sensor.
If the error is still not cleared,
call service engineer.
29
No waste toner box
Waste toner box is not set.
Set the waste toner box.
Waste toner box is set.
Call service engineer.
2A
No toner
An oscillation sound is emitted by
the toner empty sensor when there
is not enough toner in the
developing unit.
Replace with a new toner
cartridge.
There is enough toner in the
developing unit.
Call service engineer.
2C
Toner density too low
There is enough toner in the
developing unit.
Call service engineer.
Summary of Contents for SOLID F166 HD
Page 1: ...62 166 k b Engine Information...
Page 14: ...SOLID F166 HD User Manual Chapter 1 Overview...
Page 24: ...SOLID F166 HD User Manual Chapter 2 Environment...