21
To exit Special Calibration, press and hold the CAL button
for 2 seconds. The console will store any changes and revert
to normal operation.
NOTE: you must exit Special Calibration to save changes.
UNITS:
Choose the system of units desired. Turf units are
the same as English units except Area is in thousands of
square feet. Use the
“+” and “-” buttons to
choose between EnG
(American English
Units), MEt (Metric) and TurF (Turf units).
AREA
(1) (2) (3)
WIDTH
CAL
VALVE VOLTAGE:
Selects the operating voltage for the
servo valve. Factory setting is 12 volts. Use the “+” and
“-” buttons to toggle
between 8 and 12 on
display. NOTE: if using
an older Micro-Trak
servo valve, set to 8 volts.
DISTANCE
SPEED
CAL
FILL TANK SIZE:
If using the Tank feature, this setting can
be used to enter the volume of the tank. Use the “+” and “-”
buttons to choose OFF or
any value from 1-65,535.
Then when the nurse
tank is changed, the tank counter can
be reset to full by simply turning the rotary
switch to the TANK position and pressing the
“+” button. The Tank Size will be in lbs. or kg.
Anhydrous Ammonia (NH3).
TOTAL NH3
(1) (2) (3)
FLOW
CAL
VALVE RESPONSE SPEED:
Allows adjustment of
response to “tune” the system for use with very fast or
slow valves. For example, if using a ball valve
that takes several seconds to open or close
in manual mode, and the system responds
sluggishly, use the “+” button to adjust the
valve response number to 1, 2 or
3. The range of adjustment is -2
to 3, factory setting is zero.
NOTE:
Exercise caution when increasing
the valve response speed. If using a relatively fast valve (1-3
seconds open-to-close), the system may become unstable
with higher valve response speed numbers entered.
SPEED
TANK ALARM SET POINT:
Use the “+” and “-” buttons
to set the level where the Warning LED starts flashing and
the word “FILL” flashes on the display. Range is OFF or
1-65,535. When the tank
value drops below the
set point, the alarms will
notify the user that the
tank level is low.
NH3 PER
MINUTE
MIN
FLOW
AUTO SHUTOFF ON/OFF:
When Auto Shutoff is enabled
(ON) the servo will run toward minimum flow for 4 seconds
any time the system is put in HOLD or all
booms are turned off, or if in AUTO mode and
speed goes to zero. This
feature is normally used
only in Dry Application
systems.
TANK (NH3)
ADJUST
RATE
AUTO DELAY TIME:
Typically used when using relatively
slow ball valves for boom shut-off, this feature
delays adjustment of the servo valve until the
boom valves are open. Use “+” and “-” buttons to
set from zero (OFF) to 4 seconds.
RATE
ACTUAL “N”
TARGET
RATE
AREA/
HOUR
AREA/HOUR:
Not used in ”Special Cal”.
“Special” Calibration
(cont)
Entering “Special” Calibration Values