Page 28
Installation and Mounting
optoNCDT ILR 1191
5.5
Profibus
Read this chapter, if you work with a ILR 1191-300(04) sensor.
Connection to the Profibus is accomplished via a 5-pole, B-encoded M12 male connectors. Use shielded
cables for connection.
Pin Assignment Profibus IN
Assignment Profibus OUT
1
n.c.
3
4
1
5
2
5 V
4
3
2
5
1
2
A
A
3
n.c.
Ground
4
B
B
5
Screen
Screen
For operation via Profibus, other Profibus participants may connect to the 5-pole male connectors (A-cable,
B-cable). The Profibus may terminate or continue at the 5-pole male connector Profibus OUT. Some kind of
termination device must always be provided at the end of the Profibus. Supply voltage for the bus termina-
tor is available at Profibus-OUT. The 5 V are electrically isolated from the supply voltage (VCC) and rated for
loads up to 100 mA. The termination impedance is available as an optional accessory.