Page 25
Installation and Mounting
optoNCDT ILR 1191
objects. Parameter settings are made via the serial interface. The command to achieve this is Q1w_x_y_z or
Q2w_x_y_z (where “_” is equivalent to space, 0x20 hex), see Chap.
10.3.13
. The logic behavior of the switch-
ing output is determined through the parameter “z“, see
Fig. 15
.
I
L
≤0.2A
+V
bb
ILR 1191
red +U
V
red/blue
K/M
gray/pink
or blue
L
G
U
V
GND
I
L
= 10 ... 500 mA
red
red/blue
gray/pink
Q2
blue Q1
Target
Status
Q1
Q2
Link
Fig. 14 Wiring switching outputs
y
y
x
LOW
LOW
Q
1
, Q
2
Q
1
, Q
2
HIGH
HIGH
w
z = 1
z = 0
w Alarm center
x Alarm width; x ≥ 0; x ≥ y
y Alarm hysteresis; y ≥ 0
z Switching state; z = 0 or 1
LOW equal with a voltage of < 1 V
HIGH equal with a voltage of VCC - 1 V
Fig. 15 Behavior of the digital switching outputs
If:
- z = 1, increasing distance
Output switches from LOW to HIGH, if w + y/2 is exceeded,
Output switches from HIGH to LOW , if w + x + y/2 is exceeded.
- z = 0, decreasing distance
Output switches from HIGH to LOW , if w + x -y/2 is fallen below.
Output switches from LOW to HIGH, if w - y/2 is fallen below.