Page 41
Measuring Setup and Commissioning
optoNCDT 22xx
Controller 1
Controller 2
Controller 3
Controller n
PC1800-3/10/RS485(05)
PC1800-3/10/RS485(06)
PC1800-3(05)
PC1800-3(06)
PC1800-3/10/RS485(05)
PC1800-3/10/RS485(07)
PC1800-3/10/RS485(06)
PC1800-3(05)
PC1800-3(10)
PC1800-3(06)
PC1800-3/10/RS485(05)
PC1800-3/10/RS485(07)
PC1800-3/10/RS485(07)
PC1800-3/10/RS485(06)
PC1800-3(05)
PC1800-3(10)
PC1800-3(10)
PC1800-3(06)
PC2200-x
PC2200-x
PC2200-x
PC2200-x
Master
Slave
Slave
Slave
Required cables to synchronize two, three or more controllers.
Fig. 21
Alternatively, a synchronization with the interface card IF2008 and PC2200-x/IF2008 is possible.
6.8
Responses of the Analog Output to Errors
Responses of the analog output to errors:
Save the last valid measurement value (standard) or
-
Analog voltage greater than 10 VDC
-
You can change the responses of the analog output to errors as
follows:
Press and hold the
Zero/Reset
key on the controller
Switch the controller on.
After switching on, the output response alternatives will be
enabled internally in cycle and each one indicated via the LEDS
avg1 and avg2 for 1 second each, see
Fig. 22
:
Output response
LED
Status
Output voltage greater than 10 VDC AVG 1 ON
Save last valid reading
AVG 2 ON
Fig. 22 Selection output behavior