Data Channels and Switching Configuration
NetRunner W
AN User’s Manual
5-2
COMMAND FACILITY MAIN MENU
10
RESET
RESET
1
NODE
ENTER A “Y” TO CONFIRM OR “N” TO ABORT:
Y
Reset node
PARAMETER RESTORATION
2
CURRENT CONFIGURATION
Sync Channels
The ports that can be configured as sync are A2A6
1
on the CCM and all ports
on the 5000E/6 and 5000E/6DMA
2
CEM modules. Sync channels are only
supported as direct attachments to an Integration unit (not MICOM muxes).
CAUTIONS
!
D
Sync channels are not switchable and
must
be force
connected, refer to Force Connections page 5-22 for this
procedure.
D
Unless you have an NMS module installed, you must leave
one port configured for async (to access the Command
Facility).
__________
1
For the NetRunner 50E and 75E: either A2 or A3 - only one at a time can be sync. If A2 is configured for
sync, A3 cannot be, and vice versa.
2
NetRunners 1000E, 2000E and 2000ED.