Link and Port Configuration
NetRunner W
AN User’s Manual
4-29
Local Management Protocol Parameters
If you select either Annex D or LMI Rev. 1 local management protocol, you
may set the management parameters using the following path:
FRAME RELAY PARAMETERS
LOCAL MANAGEMENT PROTOCOL PARAMETERS
2
LOCAL MANAGEMENT PROTOCOL PARAMETERS
1.
FULL STATUS POLLING COUNTER
2.
ERROR THRESHOLD
3.
MONITORED EVENTS COUNT
4.
LINK INTEGRITY VERIFICATION TIMER
5.
POLLING VERIFICATION TIMER
6.
ACCESS LINK MODE
Option
Default
Description
1. Full Status Polling
Counter
6
The frequency that full status reports are made relative to
the status inquiry polls (1-255).
2. Error Threshold
3
The number of errors that need to occur in the last
monitored events (next option) before the link is
considered down (1-10).
3. Monitored Events
Count
4
The number of consecutive events that are monitored to
determine the link status (1-10).
4. Link Integrity
Verification Timer
10
The number of seconds after which the unit will send a
status inquiry to the frame relay network (5-30 seconds).
5. Polling Verification
Timer
15
If the network does not receive a valid status inquiry
within the time configured (in seconds), it reports an error
(5-30 seconds).
6. Access Link Mode
User
Selects whether the user or the network will generate
statistics for the access link. (Network = Links connected
to frame relay access devices (FRADs); User = other
applications)