2.0 Technical Specification
MODEL
SMART SWING 3®
Application
Low Energy
Door Weight (max)
325 lbs (145kg) per leaf
Operator Dimensions
5 ½” 140 mm (H) x 4 ½” 115mm (D)
Operator Net Weight
16kg Approx.
Power supply 00
90V ~ 250V AC, 50/60Hz
Consumption
100W Max
Motor
1/8 hp, 24VDC, 3A max
Rated operation
Continuous opening and closing cycles
Closing force
Adjustable Pressure by Spring Tension
Operation during power failure
Low manual resistance when opened by hand. Door closing by spring.
Motor
Low Revolution Brush DC motor
Reduction gear
Enclosed Reduction Gear system
Control system
Microprocessor Digital Control
Braking (Open Back Check & Close
Latch)
Adjustable by Control Unit
Opening
time
Full Closed to Back
Check
Adjustable (Open Speed in 20 Steps)
Back Check to Full Open
Adjustable (Back Check Speed in 5 Steps / Back Check Distance in 15 Steps)
Closing
time
Full Open to Latch
Adjustable (Close Speed in 15 Steps)
Latch to Full Closed
Adjustable (Latch Speed in 5 Steps / Latch Distance in 15 Steps)
Hold Open
Pulsed Energy to Motor. No overheating. Continuous Hold Open
Obstruction Detection (Without
safety sensor)
Opening: If door detects obstruction, power is cut to motor. (Sensitivity adjustable by
‘Current Overload’ setting) Door will close by spring power at low speed.
Obstruction Detection (With
safety sensor)
Safety sensor connected to Safety 1 input will prevent a door opening or prevent the
door to go in the closing cycle when the safety sensor is active. Safety sensor
connected to Safety 2 input will stall or crawl (Installer selectable) the door when the
safety sensor is active.
Electro-magnetic lock system
Output available
Operating environment
Ambient temperature -18 deg ~ +50 deg. (no condensation or icing)
Ambient humidity 30% to 85%RH (no hazardous materials must be present in the
atmosphere)