22
Operator's Manual
TROUBLESHOOTING
SYMPTOM
PROBABLE
CAUSE
REMEDY
Pump motor will not run.
Circuit overload.
Check wall breaker or fuse.
GFCI
tripped.
Reset.
Motor overload.
Reset thermal overload button on
pump
motor
or
inside
electrical
control
panel.
Auto Start/Stop in use.
Point gun in a safe direction and
squeeze
trigger.
No discharge at nozzle when
Inadequate water supply.
Ensure hose is 3/4" diameter and
trigger mechanism is squeezed.
incoming water supply is turned on.
Low or fluctuating pressure.
Kink in water inlet hose.
Remove kink.
Kink in high pressure discharge hose.
Replace kinked high pressure hose.
Water inlet screen obstructed.
Remove screens, clean or replace.
See pg. 12, Water Supply.
Pump sucking air. (Prime eliminated)
Tighten all water intake connections
Eliminate
leaks
in
intake
line.
Adjustable Grip on Dual Lance
Turn grip
counterclockwise
to move
is not in high pressure mode.
to high pressure.
Obstructed or worn spray nozzle.
Remove, clean or replace.
Damaged or obstructed valve assy.
Remove, clean or replace.*
on
pump.
Pump
packings
worn.
Replace
packings.*
Unloader/Bypass valve not operating
Repair or replace.*
correctly.
Scale build up in heat exchanger coil.
Delime coil as explained on pg. 21.
Water is leaking from Thermal Relief
Water inlet temperature is too high.
Incoming water temperature must be
Valve.
less
than
125°.
Water temperature is too high.
Do not allow unit to operate in
bypass
mode
(with
the
trigger
gun
closed) for more than five minutes.
Defective
valve.
Replace.*
Oil appears milky or foamy.
Water in oil.
Change pump oil. Fill to proper
level.
Oil leaking from unit.
Worn seals or o-rings.
Contact Customer Service.
Detergent will not siphon .
Detergent strainer is not completely
Check, submerge if necessary.
submerged in detergent solution.
Detergent strainer obstructed.
Inspect, clean or replace.
Detergent hose cut, obstructed or
Inspect, clean or replace.
kinked.
Detergent adjusting knob turned to
Open adjusting knob. Refer to page
closed position.
16, "Cleaning with Detergents".
Nozzle assembly is plugged.
Clean or replace.
.
Ball & Spring in detergent strainer
Remove, clean or replace.
stuck.
*See separate Parts List for detailed views or explanations.
Summary of Contents for HHB Series
Page 8: ...8 Operator s Manual HHS FEATURES FEATURES HHS_HHB 021714 RJA ...
Page 32: ...32 Manuel de l utilisateur ÉLÉMENTS CONSTITUTIFS DU HHS FEATURES HHS_HHB 021714 RJA ...
Page 73: ...Manual del operario de las lavadoras de chorro a presión 73 NOTA ...
Page 74: ...74 Manual del operario de las lavadoras de chorro a presión NOTA ...