57
Standard setting of the R-Net driving parameters, pro-
file 1, 2, 8 w/o stability sensor (ESP)
The parameter values in the following tables are selected so
that the inspection requirements of the CE certification are
fulfilled.
Profile allocation
Profile
Universal
1
Omni
2
Accompanying person
8
Standard setting of the R-Net-driving parameter up to 6 km/h (only model 1.610 / 1.611
/ 1.612 / 1.615 / 1.616) w/o stability sensor (ESP)
Number of enable Drive Profiles
1
2
8
maximum / minimum
Forward Speed [%]
90 / 15
90 / 15
90 / 15
Reverse Speed [%]
30 / 10
30 / 10
30 / 10
Turn Speed [%]
20 / 10
20 / 10
20 / 10
Forward Acceleration
10 / 0
10 / 0
10 / 0
Forward Deceleration
60 / 5
50 / 5
60 / 5
Reverse Acceleration
10 / 0
10 / 0
10 / 0
Reverse Deceleration
20 / 0
20 / 0
20 / 0
Turn Acceleration
15 / 3
15 / 3
10 / 3
Turn Deceleration
15 / 5
15 / 5
15 / 5
Power [%]
100
100
100
Torque [%]
100
100
100