WESROC© RMS Satellite Repeater – User Manual
Metrotel Corporation of Minnesota, Inc.
Revision A. May 7, 2008
Page 9
Satellite Repeater Status Screen
Screen 2 shows more general information about the Satellite Repeater:
1. Number of transmitters initialized to the Satellite Repeater. The
maximum number of transmitters supported by one Satellite Repeater
is sixteen.
2. Number of minutes remaining for Init Mode. This is used for verifying
that the Satellite Repeater is still in initialization mode during a system
installation. See detailed description of initialization mode in operation
section of this document.
3. Cold Boots. (Total times power has been removed from and applied to
the satellite repeater). This is a useful diagnostic if unusual operation is
occurring due to frequent power failures. This number will not increase
after 65535 cold boots.
4. Up Time. Number of minutes the Satellite Repeater has operated since
the last cold boot. This is also a useful indicator of the reliability of the
power source.
5. Total number of packets sent to Globalstar network. This is in place as
a potential reconciliation tool in case there is a discrepancy between
received reports and expected reports from a given Satellite Repeater.
To view the next screen, press the down button.